Store the Fluid Cartridge

If a usable fluid cartridge has been exposed to chemical
and removed from the gun, store the cartridge in a
moisture-free environment.
1. Rinse off any residual chemical with a compatible
solvent.
2. Submerge the cartridge in an acceptable storage
liquid. See Acceptable Cartridge Storage
Liquids, page 39.
To prevent cured material on sealing surfaces and
passages, store cartridges in a moisture-free
environment. Exposure to air can result in cured
material. Cured material can obstruct passages and
damage seals.
Air o-rings on cartridge are not chemically resistant.
Soaking cartridge in solvent will cause o-rings to
swell.

Clean Gun Surface

Keep gun clean with accessory gun cover.
Applying a light coat of lubricant will make cleaning
easier.
Wipe off outside of gun with compatible solvent.
Use N Methyl Pyrrolidone (NMP), Dynaloy
Dynasolve CU-6, SB Versaflex-brand Dzolv
equivalent to soften cured material.

Clean Air Cap

Soak air cap in compatible solvent. Clean holes with #58
(0.042) drill bit.

Lubrication

Liberally lubricate all o-rings, seals, and threads.
Lubricate threads and outside of lock ring (11). See
Lubricant for Gun Rebuild, page 43 to order lubricant.
3A7314B
NOTICE
NOTICE
®
-brand
®
, or

Inspect the Piston Safety Lock

1. Follow the Pressure Relief Procedure, page 19.
2. Disconnect air line quick coupler (D) and remove
fluid manifold (M).
M
3. Unscrew cylinder cap (5). Hold piston stop (28) with
wrench and unscrew from safety lock (4). Inspect
spring (30) and o-rings (14, 24).
28
4. Liberally lubricate o-rings and reassemble. Clean
threads with solvent or alcohol. Apply
medium-strength Loctite® or equivalent to threads
on stop (28) and reassemble.
5. Attach the fluid manifold.
6. Connect air. Return gun to service.

Clean Fluid Manifold

Clean fluid manifold sealing faces with compatible
solvent and a brush whenever removed from gun. Be
sure to clean the two fluid ports (FP) in the top mating
surface. Do not damage the flat sealing surfaces. Coat
with grease if left exposed, to seal out moisture.
FP
Maintenance