Daily Shutdown - Graco Fusion A Series Instructions Manual

Pc spray gun
Hide thumbs Also See for Fusion A Series:
Table of Contents

Advertisement

Daily Shutdown

Grease your gun daily to prevent two component curing
and keep fluid passages clean. Purge air carries grease
mist through the air chamber (AC) and impingement
ports (IP) and out the mix chamber nozzle (N), coating
all interior surfaces.
Key
Purge Air
Fluid
Cleanoff Air
Grease
G
19
3A7314B
1. Follow the Pressure Relief Procedure, page 19.
2. Leave the air turned on and gun detriggered.
3. Remove the grease fitting cap. Using the grease
gun (ZB), dispense grease into fitting (G) until
grease mist sprays from mix chamber nozzle (N).
NOTE: Do not over-grease. Use two shots maximum.
Do not spray grease mist on sprayed material.
4. Replace the grease cap.
5. Turn off the air valve (W).
AC
IP
N
ZB
G
N
TI2415A
Operation
W
21