Connect Ec-Screwdriver Spindle To Ast(I)6 Sequence Controller - Deprag MINIMAT-EC 320E22-00120 Operating Instruction Booklet

Ec-screwdriver spindle for stationary use
Table of Contents

Advertisement

6.5. Connect EC-Screwdriver Spindle to AST(i)6 Sequence Controller

see chapter DIMENSION SHEET as well as Instructions „Sequence Controller AST(i)6"
CAUTION
Differing power supplies can result in injuries to persons or damage to
the equipment
Before connecting electrical power, insure that your power supply is
compatible with that recommended for the controller ( Technical Data).
ATTENTION
During operation malfunctions or damages can be caused to the
contacts.
Fully tighten the plug connection!
IMPORTANT
For more information about the start-up of the sequence controller, read the
quick-start instructions of sequence controller AST(i)6 with
320E....Screwdriver which is also included in delivery.
Plug-in the motor cable at the sequence
controller and fix it.
Connect the sequence controller to the power
supply. Switch on the sequence controller on
main switch.
Enter the calibration value and the value of the
calibration offset in the sequence controller.
You will find this values in the calibration
certificate (
Operation Instruction "Sequence
Controller AST(i)6").
14