*6. The built-in EtherNet/IP port uses the TCP/UDP port numbers shown in the following table.
Do not set the same port number for more than one TCP/UDP service.
Service
Tag data links
Used by system
CIP messages
FTP client (Data transfer port)
DNS client
BOOTP client
HTTP server
Used by system, other
FTP client (Control port)
TCP/UDP message service
NTP client
SNMP agent
SNMP trap
Safety Control Units
Safety CPU Units NX-SL5500/SL5700
Unit name
Model
Maximum number of safety I/O points
Program capacity
Number of safety master connections *1
I/O refreshing method
External connection terminals
Indicators
Hardware switch settings
Dimensions
I/O power supply method
Current capacity of I/O power supply terminals
NX Unit power consumption
Current consumption from I/O power supply
Weight
Installation orientation and restrictions
*1. This is the number of safety I/O connections for the Unit. The value is the total number of CIP Safety originator connections
target connections
2, and FSoE master connections
*
*2. You can establish a unidirectional input or output communication with a CIP Safety target device for each connection. Two connections are
used for establishing bidirectional input and output communications.
*3. You can establish a unidirectional input or output communication with a CIP Safety originator device for each connection. Two connections are
used for establishing bidirectional input and output communications.
For the input direction only, it is possible to communicate with multiple CIP Safety originator devices by using a single connection.
*4. You can establish bidirectional input and output communications with an FSoE slave device for each connection.
*5. The cable length for the Units (Communication Control Unit and Power Supply Unit for NX Units) that supply power to the corresponding Unit
must be up to 20 m.
Type
UDP
2222
UDP
2223, 2224
TCP
9610
TCP
44818
TCP
20
TCP/UDP
53
UDP
68
TCP
80
TCP/UDP
9600
TCP
21
TCP/UDP
64000
UDP
123
UDP
161
UDP
162
NX-SL5500
1024 points
2048 KB
128
Free-Run refreshing
None
[TS] indicator, [NS] indicator, [FS] indicator, [P ERR]
indicator, [RUN] indicator,
[VALID] indicator, [DEBUG] indicator, seven-segment
indicator
Seven-segment indicator
[TS] LED
[NS] LED
[FS] LED
[P ERR] LED
[RUN] LED
[VALID] LED
[DEBUG] LED
[SERVICE] switch, [SETTING] switch
30 × 100 × 71 mm (W × H × D)
Not supplied.
No I/O power supply terminals
3.35 W max. *5
No consumption
130 g max.
Only upright installation orientation
2.
*
NX-CSG/SL5/SI/SO
Port number
Fixed values
You can change the port number in the Unit
Settings on the Sysmac Studio.
Safety CPU Unit
NX-SL5700
2032 points
4096 KB
254
[TS] indicator, [NS] indicator, [FS] indicator, [P ERR]
indicator, [RUN] indicator,
[VALID] indicator, [DEBUG] indicator, seven-segment
indicator
Seven-segment indicator
[TS] LED
[NS] LED
[P ERR] LED
[VALID] LED
[SERVICE] switch, [SETTING] switch
Remarks
[FS] LED
[RUN] LED
[DEBUG] LED
2, CIP Safety
*
8