Quick repair pump
Table of Contents

Advertisement

Pressure Relief
6.
Hold a metal part of the gun firmly to a
grounded metal pail. Trigger the gun to
relieve pressure.
7.
Engage the trigger lock.
6
8.
Open any fluid drain valves in system.
Leave drain valves open until ready to
spray again.
ti24585a
9.
If you suspect the spray tip or hose is
clogged or that pressure has not been
fully relieved:
a.
b.
c.
VERY SLOWLY loosen tip guard
retaining nut or hose and coupling to
relieve pressure gradually.
Loosen nut or coupling completely.
Clear hose or tip obstruction.
ti24608a
3A4347D