Johnson Controls York YKN2Open board Technical Information page 39

Table of Contents

Advertisement

8
Communications
8.1
YKN2Open board
N2OpenType
N2OpenId
BI
45
BI
46
BI
47
BI
48
BI
49
BI
50
BI
51
BI
52
BI
53
Outdoor Temperature favourable
BI
54
BI
55
Water temperature favourable
BI
56
BI
57
Auxiliary Stage 1 Present
BI
58
Auxiliary Stage 2 Present
BI
59
Auxiliary Stage 3 Present
BI
60
Auxiliary Stage 4 Present
BI
61
BI
62
BI
63
BI
64
BI
65
Smoke Detector Present
BI
66
Dirty Filters Detector Present
BI
67
BI
68
BI
69
BI
70
DCP-1 Thermostat Present
BI
71
BI
72
Discharge Temperature 1
BI
73
BI
74
BI
75
BI
76
Liquid Temperature 1 Low
BI
77
Discharge Temperature 2
BI
78
BI
79
BI
80
BI
81
Liquid Temperature 2 Low
BI
82
BI
83
BI
84
BI
85
36
Value
Description
/
Units
Gas Stage 2
OFF/ON
(out)
Gas Stage 3
OFF/ON
(out)
Gas Stage 4
OFF/ON
(out)
Aux Stage 1
OFF/ON
(out)
Aux Stage 2
OFF/ON
(out)
Aux Stage 3
OFF/ON
(out)
Aux Stage 4
OFF/ON
(out)
Exhaust fan
OFF/ON
(out)
Inactive /
Active
Water pump
OFF/ON
Inactive /
Active
Dirty Filters (out)
Clean / Dirty
Absent /
Present
Absent /
Present
Absent /
Present
Absent /
Present
Absent /
Compressor 2 Present
Present
Absent /
Compressor 3 Present
Present
Absent /
Economiser Present
Present
Absent /
Water Heater Present
Present
Absent /
Present
Absent /
Present
Absent /
YkTool Enabled
Present
Absent /
Gas Control 1 Present
Present
Absent /
Gas Control 2 Present
Present
Absent /
Present
Indoor Fan Protection
OK / Fault
OK / Fault
High Pressure 1
OK / Fault
Low Pressure 1
OK / Fault
Cool Start 1 Repeated
OK / Fault
OK / Fault
OK / Fault
High Pressure 2
OK / Fault
Low Pressure 2
OK / Fault
Cool Start 2 Repeated
OK / Fault
OK / Fault
Smoke Detect
OK / Fault
Suction Probe 1 Error
OK / Fault
Suction Probe 2 Error
OK / Fault
Liquid Probe 1 Error
OK / Fault
Range
Out
Out
Out
Out
Resistor accessory 1 ON output
Out
Resistor accessory 2 ON output
Out
Resistor accessory 3 ON output
Out
Resistor accessory 4 ON output
Out
Favourable temperature
Outdoor air temperature indication favourable
< 20 ºC
Out
Favourable temperature
Water temperature indication favourable
> 30 ºC
Out
Accessory
Accessory
Accessory
Accessory
Accessory
Accessory compressor 2 present
Accessory
Accessory compressor 3 present
Accessory
Economiser accessory present
Accessory
Accessory
Smoke detector accessory present
Accessory
Accessory
Accessory
Accessory
Accessory
Alarm
Indoor fan thermal switch (14) fault
Alarm-Temperature
Discharge temperature 1 (11) fault
>130 ºC
Alarm
High-pressure switch 1 (12) fault
Alarm
Low-pressure switch 1 (13) fault
Alarm-Suction temperature
< ‑4 ºC or ‑25 ºC
Alarm-Null
Liquid temperature 1 low fault (CANCELLED)
Alarm-Temperature
Discharge temperature 2 (21) fault
>130 ºC
Alarm
High-pressure switch 2 (22) fault
Alarm
Low-pressure switch 2 (23) fault
Alarm-Suction temperature
< ‑4 ºC or ‑25 ºC
Alarm-Null
Liquid temperature 2 low fault (CANCELLED)
Alarm-High temperature or
Smoke / high-temperature detector fault (46)
Smoke
Incident-Probe error
Incident-Probe error
Incident-Probe error
Description
Gas 2 ON output
Gas 3 ON output
Gas 4 ON output
Exhaust fan ON output
Water pump ON output
Dirty filters ON output
Resistor accessory 1 present
Resistor accessory 2 present
Resistor accessory 3 present
Resistor accessory 4 present
Water coil accessory present
Dirty filter accessory present
YkTool accessory present
Gas accessory 1 present
Gas accessory 2 present
Thermostat DCP-1 Present
Repeat cold starts 1 (15) fault
Repeat cold starts 2 (25) fault
Suction probe 1 incident
Suction probe 2 incident
Liquid probe 1 incident