When the service button is briefly pressed, the parameters indicated below are momentarily changed to
the value in the test column.
Parameter
CMPTION
DFRTICONF
DFRTIMAX
DFRTISECADO
MAQTIMAN
26
Minimum supply temperature for economiser
Opening percentage to start up the air exhaust
Gas stage delay
Number of identical readings to achieve the correct entry of DS2406
Delay between start-ups of compressors
Manual operation time, economiser and water valve
Time between start ups and stops
Start-up time of the outdoor fan and the compressor
Number of faults saved
Probe time to be considered for short circuit
Temperature to be considered for open or non-existent probe
Time lapse for high-pressure switch
Time lapse for low-pressure switch
Minimum movement of the potentiometer for a change to be considered
Number of times that the thermal switch can trip in one hour
Residual heat and cold evacuation time
Electrical resistor delay
Times that the gas burner automatically resets
Time for the supply temperature to rise above 25 °C in gas stages
Suction temperature below that at which the economiser is closed
Suction temperature in order for the economiser to reopen
Supply temperature in order for the unit to stop and indicate a fault
Supply temperature in order for stages to begin to be stopped
Minimum gas supply temperature
If the supply temperature is < 14 °C and the outdoor temperature > 10 °C
compressors disabled
If the supply temperature is < 14 °C and the outdoor temperature > 12 °C
let compressors operate
The time between defrosts in accordance with SW1 and SW2.
If the supply temperature is < 14 °C and the outdoor temperature < 10 °C
only the economiser operates
Time until economiser operates
Minutes to switch to OFF after the stages stop, during which the air quality
demand can actuate
Sampling time of the demand calculation
Hysteresis of the Set-Point
Change delay time of the 4-way valve after the compressor is stopped
Stopping of the 2nd fan with a crossed coil. Fan no. 1 compressor side
Start-up of the 2nd fan with a crossed coil. Fan no. 1 compressor side
Description
Compressor delay
Defrost confirmation time
Defrost maximum time
Coil drying time
Manual operating time
Description
Value
4 min
3 min.
10 min.
1 min.
30 s.
Value
11,5 °C
30%
0 min.
5
5 sec.
30 sec.
1 sec.
4 sec.
9
-33.5 °C
93.5 °C
30 sec.
2 min.
4 LSB
3
60 sec.
0 min.
5
10 min.
0 °C
4 °C
80 °C
55 °C
25 °C
10 °C
12 °C
0', 30' ,60' ,90'
14 °C
1 sec.
20 min.
10 min.
0,25 °C
60 sec.
16 °C
19 °C
Battery
10 sec.
10 sec.
30 sec.
1 sec.
2 sec.