Commissioning
Class
Instance Attribute Data type
0x0390 1
0
1
2
3
4
0x0410 1
0
1
2
3
4
5
6
7
IF2030/ENETIP
Name
Parameter Info
Uint8
R
Number of objects
Uint16
RW Parameter ID
Uint8[14] R
Name
Uint8[8]
R
Unit
Uint8[8]
R
Type
Float parameter
Uint8
Number of objects
Uint16
RW Parameter ID
Uint8
RW Reserved
Float
RW Value
Uint8[14] R
Name
Uint8[8]
R
Unit
Float
R
Min
Float
R
Max
RS485
RS422
Description
Request configuration parameters, e.g., sensor
exposure time, request via subindex 1, configure
interface with Class 0x2510 through 0x2540
Please refer to the sensor documentation for
available parameter IDs and their types
Read or write float parameter
Please refer to the sensor documentation for
available parameter IDs and their types
Value
Designation
Unit as a string
Page 24