5.4
Class Directory
Class
Instance Attribute Data type
0x80
1
0
1
1
0x90
0
0xA0
1
0
1
2
3
4
5
6
7
8
IF2030/ENETIP
Name
Uint8
RW Select sensor
Uint8[32]
R
Sensor addresses
Uint32[64] R
Device error log
Uint32
RW Baudrate
Uint8
RW Minimum cycle time
Preferred sensor
Uint8
RW
data size
Uint8
RW Sensor interface
Uint8
W
Reset device config
Uint8
W
Reset sensor config
Uint8
W
Reset device
enable/disable
Uint8
RW
HTTL Sync
enable/disable cy-
Uint8
RW
clic status header
RS485 RS422 Description
Address of currently selected sensor
Shows address list of available sensors
Reads out the last 32 error codes with time stamp
IF2030 baud rate
Minimum time for one communication cycle in ms,
cycle time = 0: use estimated time
Desired useful data length in bytes per sensor,
value = 0: estimated/calculated value
0: RS485,
1: Reserved,
2: ASCII + RS422
One byte deletes settings from flash, settings are
included in RAM until restart
One byte deletes settings from flash, settings are
included in RAM until restart
One byte performs reset
0: Disable HTTL synchronization
1: Enable HTTL synchronization
0: Disable 8 byte status header in cyclic data
1: Enable 8 byte status header in cyclic data