Parameter

6
Parameter
For optimum operation you need to configure your frequency inverter for the specific requirements
and specifications of the connected drive system and your application. All the necessary settings are
stored in numbered parameters in the inverter's memory – you only have to set them once because
this memory is not cleared when the power is switched off. All the parameters are preset to default val-
ues when the inverter leaves the factory so that the unit can be used at once.
There are two main classes of parameters, simple mode parameters and extended parameters. The
simple mode parameters should always be checked and configured before using the inverter but
many of the extended parameters are only needed for special or complex applications.
CAUTION:
E
Incorrect parameter settings can damage or (in extreme cases) even destroy the connected
motor. Take great care when you are setting the parameters and double-check the electrical
and mechanical specifications of the motor, your entire drive system and the connected ma-
chine before proceeding.
6.1

Simple mode parameters

Simple mode parameters of the FR-A800 inverters
Para-
Name
meter
0
Torque boost
1
Maximum frequency
2
Minimum frequency
3
Base frequency
Multi-speed setting (high speed) -
4
RH
Multi-speed setting (medium speed)
5
- RM
6
Multi-speed setting (low speed) -RL
7
Acceleration time
8
Deceleration time
9
Electronic thermal O/L relay
79
Operation mode selection
Terminal 2 frequency setting gain
125
frequency
Terminal 4 frequency setting gain
126
frequency
160
User group read selection
998
PM parameter initialization
999
Automatic parameter setting
The setting depends on the inverter capacity.
NOTE
You can find a reference list of all inverter parameters in the Appendix (section A.1).
Frequency Inverters - Beginner's Guide
FR-A800
Initial Value
Setting
Range
FM-type CA- type
0–30 %
1/2/3/4/6 %
0–120 Hz
60 /120 Hz
0–120 Hz
0 Hz
0–590 Hz
60 Hz
50 Hz
0–590 Hz
60 Hz
50 Hz
0–590 Hz
30 Hz
0–590 Hz
10 Hz
0–3600 s
5/15 s
0–3600 s
5/15 s
0–3600 A
Rated current
0–4/6/7
0
0 to 590 Hz
60 Hz
50 Hz
0 to 590 Hz
60 Hz
50 Hz
0, 1, 9999
0
0, 3003, 3103,
8009, 8109,
0
9009, 9109
1, 2, 10, 11, 12,
13, 20, 21,
9999
9999
Simple mode parameters
6 - 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820Fr-a840Fr-a842Fr-a846

Table of Contents