Mitsubishi Electric FR-A800 Series Beginner's Manual page 77

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Appendix
Param-
Name
eter
RUN terminal function
190
selection
SU terminal function
191
selection
IPF terminal function
192
selection
OL terminal function
193
selection
FU terminal function
194
selection
ABC1 terminal function
195
selection
ABC2 terminal function
196
selection
232–
Multi-speed setting
239
(speeds 8 to 15)
Soft-PWM operation
240
selection
Analog input display unit
241
switchover
Terminal 1 added
242
compensation amount
(terminal 2)
Terminal 1 added
243
compensation amount
(terminal 4)
Cooling fan operation
244
selection
245
Rated slip
Slip compensation time
246
constant
Constant-power range
247
slip compensation
selection
Self power management
248
selection
Earth fault detection at
249
start
Frequency Inverters - Beginner's Guide
Setting Range
Initial Value
0–8, 10–20, 22,
0
25–28, 30–36,
38–54, 56, 57, 60,
61, 63, 64, 68, 70,
79, 84, 85, 90
to99, 100–108,
110–116, 120,
122, 125–128,
130–136,
138–154, 156,
157, 160, 161,
163, 164, 168,
170, 179, 184,
185, 190–199,
200–208,
300–308,
9999
1
2/9999/2
3
4
99
9999
0–590 Hz, 9999
9999
0, 1
1
0, 1
0
0–100 %
100 %
0–100 %
75 %
0, 1, 101–105
1
0–50 %, 9999
9999
0.01–10 s
0.5 s
0, 9999
9999
0–2
0
0, 1
0
Param-
Name
eter
250
Stop selection
Output phase loss
251
protection selection
252
Override bias
253
Override gain
Main circuit power OFF
254
waiting time
255
Life alarm status display
Inrush current limit
256
circuit life display
Control circuit capacitor
257
life display
Main circuit capacitor life
258
display
Main circuit capacitor life
259
measuring
PWM frequency
260
automatic switchover
Power failure stop
261
selection
Subtracted frequency at
262
deceleration start
Subtraction starting
263
frequency
Power-failure
264
deceleration time 1
Power-failure
265
deceleration time 2
Power failure
266
deceleration time
switchover frequency
Terminal 4 input
267
selection
Monitor decimal digits
268
selection
269
Parameter for manufacturer setting. Do not set.
Stop-on contact/load
torque high-speed
270
frequency control
selection
High-speed setting
271
maximum current
Middle-speed setting
272
minimum current
273
Current averaging range
Current averaging filter
274
time constant
Stop-on contact
275
excitation current low-
speed multiplying factor
PWM carrier frequency at
276
stop-on contact
278
Brake opening frequency
Parameter list (FR-A800)
Setting Range
Initial Value
0–100 s,
1000–1100 s,
9999
8888, 9999
0, 1
1
0–200 %
50 %
0–200 %
150 %
0–3600 s, 9999
600 s
(0–15)
0
(0–100 %)
100 %
(0–100 %)
100 %
(0–100 %)
100 %
0, 1
0
0, 1
1
0–2, 21, 22
0
0–20 Hz
3 Hz
0–590 Hz, 9999
60/50 Hz
0–3600 s
5 s
0–3600 s, 9999
9999
0–590 Hz
60/50 Hz
0–2
0
0, 1, 9999
9999
0–3, 11, 13
0
0–400 %
50 %
0–400 %
100 %
0–590 Hz, 9999
9999
1–4000
16
50–300 %, 9999
9999
0–9, 9999
/
9999
0–4, 9999
0–30 Hz
3 Hz
A - 5