Mitsubishi Electric FR-A800 Series Beginner's Manual page 82

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Parameter list (FR-A800)
Param-
Name
eter
Acceleration time at a
611
restart
Brake opening current
639
selection
Brake operation
640
frequency selection
Second brake sequence
641
operation selection
Second brake opening
642
frequency
Second brake opening
643
current
Second brake opening
644
current detection time
Second brake operation
645
time at start
Second brake operation
646
frequency
Second brake operation
647
time at stop
Second deceleration
648
detection function
selection
Second brake opening
650
current selection
Second brake operation
651
frequency selection
653
Speed smoothing control
Speed smoothing cutoff
654
frequency
Analog remote output
655
selection
656
Analog remote output 1
657
Analog remote output 2
658
Analog remote output 3
659
Analog remote output 4
Increased magnetic
660
excitation deceleration
operation selection
Magnetic excitation
661
increase rate
Increased magnetic
662
excitation current level
Control circuit
663
temperature signal
output level
Regeneration avoidance
665
frequency gain
Power failure stop
668
frequency gain
Tuning data unit
684
switchover
686
Maintenance timer 2
Maintenance timer 2
687
warning output set time
688
Maintenance timer 3
Maintenance timer 3
689
warning output set time
A - 10
Setting Range
Initial Value
0–3600 s, 9999
9999
0, 1
0
0, 1
0
0, 7, 8, 9999
0
0–30 Hz
3 Hz
0–400 %
130 %
0–2 s
0.3 s
0–5 s
0.3 s
0–30 Hz
6 Hz
0–5 s
0.3 s
0, 1
0
0, 1
0
0, 1
0
0–200 %
0 %
0–120 Hz
20 Hz
0, 1, 10, 11
0
800–1200 %
1000 %
800–1200 %
1000 %
800–1200 %
1000 %
800–1200 %
1000 %
0, 1
0
0–40 %, 9999
9999
0–300 %
100 %
0–100 °C
0 °C
0–200 %
100 %
0–200 %
100 %
0, 1
0
0 (1–9998)
0
0–9998, 9999
9999
0 (1–9998)
0
0–9998, 9999
9999
Param-
Name
eter
690
Deceleration check time
Second free thermal
692
reduction frequency 1
Second free thermal
693
reduction ratio 1
Second free thermal
694
reduction frequency 2
Second free thermal
695
reduction ratio 2
Second free thermal
696
reduction frequency 3
699
Input terminal filter
Maximum motor
702
frequency
Induced voltage constant
706
(phi f )
707
Motor inertia (integer)
711
Motor Ld decay ratio
712
Motor Lq decay ratio
Starting resistance
717
tuning compensation
Starting magnetic pole
721
position detection pulse
width
724
Motor inertia (exponent)
Motor protection current
725
level
Second motor induced
738
voltage constant (phi f)
Second motor Ld decay
739
ratio
Second motor Lq decay
740
ratio
Second starting
741
resistance tuning
compensation
Second motor magnetic
742
pole detection pulse
width
Second motor maximum
743
frequency
Second motor inertia
744
(integer)
Second motor inertia
745
(exponent)
Second motor protection
746
current level
Appendix
Setting Range
Initial Value
0–3600 s, 9999
1 s
0–590 Hz, 9999
9999
1–100 %
100 %
0–590 Hz, 9999
9999
1–100 %
100 %
0–590 Hz, 9999
9999
5–50 ms, 9999
9999
0–400 Hz, 9999
9999
0–5000
mV/(rad/s),
9999
9999
10–999, 9999
9999
0–100 %, 9999
9999
0–100 %, 9999
9999
0–200 %, 9999
9999
0–6000 μs,
10000–
9999
16000 μs,
9999
0–7, 9999
9999
100–500 %, 9999
9999
0–5000
mV/(rad/s),
9999
9999
0–100 %, 9999
9999
0–100 %, 9999
9999
0–200 %, 9999
9999
0–6000 μs,
10000–16000 μs,
9999
9999
0–400 Hz, 9999
9999
10–999, 9999
9999
0–7, 9999
9999
100–500 %, 9999
9999

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820Fr-a840Fr-a842Fr-a846

Table of Contents