Param-
Name
eter
Swinging suppression
1074
frequency
Swinging suppression
1075
depth
Swinging suppression
1076
width
1077
Rope length
1078
Trolley weight
1079
Load weight
Deceleration time at
1103
emergency stop
1106
Torque monitor filter
Running speed monitor
1107
filter
Excitation current
1108
monitor filter
PROFIBUS
communication
1109
command source
selection
PROFIBUS format
1110
selection
Speed limit method
1113
selection
Torque command
1114
reverse selection
Speed control integral
1115
term clear time
Constant output range
1116
speed control P gain
compensation
Speed control P gain1
1117
(per-unit system)
Speed control P gain2
1118
(per-unit system)
Model speed control gain
1119
(per-unit system)
Per-unit speed control
1121
reference frequency
PID upper limit
1134
manipulated value
PID lower limit
1135
manipulated value
Second PID display bias
1136
coefficient
Second PID display bias
1137
analog value
Second PID display gain
1138
coefficient
Second PID display gain
1139
analog value
Second PID set point/
1140
deviation input selection
Second PID measured
1141
value input selection
1142
Second PID unit selection
1143
Second PID upper limit
1144
Second PID lower limit
Frequency Inverters - Beginner's Guide
Setting Range
Initial Value
0.05–3 Hz, 9999
1 Hz
0–3
0
0–3
0
0.1–50 m
1 m
1–50000 kg
1 kg
1–50000 kg
1 kg
0–3600 s
5 s
0–5 s, 9999
9999
0–5 s, 9999
9999
0–5 s, 9999
9999
Parameter for option FR-A8NP
0–2, 10, 9999
9999
0, 1
1
0–9998 ms
0 s
0–100 %
0 %
0–300, 9999
9999
0–300, 9999
9999
0–300, 9999
9999
0–400 Hz
120 Hz
60 Hz
0–100 %
100 %
0–100 %
100 %
0–500, 9999
9999
0–300 %
20 %
0–500, 9999
9999
0–300 %
100 %
1–5
2
1–5
3
0–43, 9999
9999
0–100 %, 9999
9999
0–100 %, 9999
9999
Param-
Name
eter
Second PID deviation
1145
limit
Second PID signal
1146
operation selection
Second output
1147
interruption detection
time
Second output
1148
interruption detection
level
Second output
1149
interruption cancel level
1150–
PLC function user
1199
parameters1 to 50
Target position/speed
1220
selection
Start command edge
1221
detection selection
First positioning
1222
acceleration time
First positioning
1223
deceleration time
First positioning dwell
1224
time
First positioning
1225
sub-function
Second positioning
1226
acceleration time
Second positioning
1227
deceleration time
Second positioning dwell
1228
time
Second positioning
1229
sub-function
Third positioning
1230
acceleration time
Third positioning
1231
deceleration time
Third positioning dwell
1232
time
Third positioning
1233
sub-function
Fourth positioning
1234
acceleration time
Fourth positioning
1235
deceleration time
Fourth positioning dwell
1236
time
Fourth positioning
1237
sub-function
Fifth positioning
1238
acceleration time
Fifth positioning
1239
deceleration time
Parameter list (FR-A800)
Setting Range
Initial Value
0.0–100.0 %,
9999
9999
0–3, 10–13
0
0–3600 s, 9999
1 s
0–590 Hz
0 Hz
900–1100 %
1000 %
0–65535
0
0–2
0
0, 1
0
0.01–360 s
5 s
0.01–360 s
5 s
0–20000 ms
0 ms
0, 1, 10, 11, 100,
10
101, 110, 111
0.01–360 s
5 s
0.01–360 s
5 s
0–20000 ms
0 ms
0, 1, 10, 11, 100,
10
101, 110, 111
0.01–360 s
5 s
0.01–360 s
5 s
0–20000 ms
0 ms
0, 1, 10, 11, 100,
10
101, 110, 111
0.01–360 s
5 s
0.01–360 s
5 s
0–20000 ms
0 ms
0, 1, 10, 11, 100,
10
101, 110, 111
0.01–360 s
5 s
0.01–360 s
5 s
A - 15