Mitsubishi Electric FR-A800 Series Beginner's Manual page 76

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

Parameter list (FR-A800)
Param-
Name
eter
134
PID differential time
Electronic bypass
135
sequence selection
MC switchover interlock
136
time
137
Start waiting time
138
Bypass selection at a fault
Automatic switchover
frequency between
139
inverter and commercial
power-supply operation
Backlash acceleration
140
stopping frequency
Backlash acceleration
141
stopping time
Backlash deceleration
142
stopping frequency
Backlash deceleration
143
stopping time
144
Speed setting switchover
PU display language
145
selection
Acceleration/
147
deceleration time
switching frequency
Stall prevention level at 0
148
V input
Stall prevention level at
149
10 V input
Output current detection
150
level
Output current detection
151
signal delay time
Zero current detection
152
level
Zero current detection
153
time
Voltage reduction
154
selection during stall
prevention operation
RT signal function
155
validity condition
selection
Stall prevention
156
operation selection
157
OL signal output timer
AM terminal function
158
selection
A - 4
Setting Range
Initial Value
0.01–10.00 s,
9999
9999
0, 1
0
0–100 s
1 s
0–100 s
0.5 s
0, 1
0
0–60 Hz, 9999
9999
0–590 Hz
1 Hz
0–360 s
0.5 s
0–590 Hz
1 Hz
0–360 s
0.5 s
0, 2, 4, 6, 8, 10,
102, 104, 106,
4
108, 110, 112
0–7
1
0–590 Hz,9999
9999
0–400 %
150 %
0–400 %
200 %
0–400 %
150 %
0–10 s
0 s
0–400 %
5 %
0–10 s
0.5 s
0, 1, 10, 11
1
0, 10
0
0–31, 100, 101
0
0–25 s, 9999
0 s
1–3, 5–14, 17, 18,
21, 24, 32–34, 50,
1
52–54, 61, 62, 67,
70, 87–90, 91–98
Param-
Name
eter
Automatic switch-over
frequency range from
159
bypass to inverter
operation
User group read
160
Simple
Simple
Simple
selection
Frequency setting/key
161
lock operation selection
Automatic restart after
162
instantaneous power
failure selection
First cushion time for
163
restart
First cushion voltage for
164
restart
Stall prevention
165
operation level for restart
Output current detection
166
signal retention time
Output current detection
167
operation selection
168
Parameter for manufacturer setting. Do not set.
169
170
Watt-hour meter clear
Operation hour meter
171
clear
User group registered
172
display/batch clear
173
User group registration
174
User group clear
STF terminal function
178
selection
STR terminal function
179
selection
RL terminal function
180
selection
RM terminal function
181
selection
RH terminal function
182
selection
RT terminal function
183
selection
AU terminal function
184
selection
JOG terminal function
185
selection
CS terminal function
186
selection
MRS terminal function
187
selection
STOP terminal function
188
selection
RES terminal function
189
selection
Appendix
Setting Range
Initial Value
0–10 Hz, 9999
9999
0, 1, 9999
0
0, 1, 10, 11
0
0–3, 10–13
0
0–20 s
0 s
0–100 %
0 %
0–400 %
150 %
0–10 s, 9999
0.1 s
0, 1, 10, 11
0
0, 10, 9999
9999
0, 9999
9999
9999, (0–16)
0
0–1999, 9999
9999
0–1999, 9999
9999
60
61
0
1
0–20, 22–28, 37,
42–47, 50, 51,
60–62, 64–74,
2
76–80, 87, 92, 93,
9999
3
4
5
6
24/10/24
25
62

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-a820Fr-a840Fr-a842Fr-a846

Table of Contents