Graco 127650 Instructions Manual page 13

Metered automatic shut-off nozzle for diesel exhaust fluid (def) (iso 22241), max wpr 345 kpa;
Table of Contents

Advertisement

Available languages

Available languages

NOTE
The flow rate is measured with reference to the
unit of measurement of the Partial. For this reason,
in case of the unit of measurement of the Partial
and Total being different, as in the example shown
below, it should be remembered that the indicated
flow rate relates to the unit of measurement of the
partial. In the example shown, the flow rate is ex-
pressed in Qts/min.
The word "Gal" remaining alongside the fl w rate refers to
the register of the Totals (Reset or NON Reset) which are
again displayed when exiting from the fl w rate reading
mode.
To return to "Normal" mode, press the CAL key again. If one of the two keys RESET or
CAL is accidentally pressed during the count, this will have no effect.
NOTE
Even though in this mode they are not displayed, both
the Reset Total and the General Total (Total) increase.
Their value can be checked after dispensing has
terminated, returning to "Normal" mode, by quickly
pressing CAL.
J2.1
PARTIAL RESET (FLOW RATE MODE)
To reset the Partial Register, finish dispensing and wait for the Remote
Display to show a Flow Rate of 0.0 as indicated in the illustration
then quickly press RESET
M0303
EN
13

Advertisement

Chapters

Table of Contents
loading

Table of Contents