I2 BATTERY HOUSING
FIRE AND EXPLOSION HAZARD
WARNING
Battery replacement may create a static discharge
which has potential to ignite an explosive atmo-
sphere. Always replace batteries in a non-explosive
atmosphere (non-hazardous) location.
NOTICE
The meter is powered by two 1.5V standard type batteries (size
AAA). The battery housing is easily accessible and is closed by a
cover with seal. Everything is easily removable by taking off the
rubber protection around the nozzle and loosening the screws
which secure the cover.
J
DAILY USE
FOREWORD
The only operations that need to be done for daily use are partial and/or reset-
table total register resetting. Occasionally the meter may need to be configu ed
or calibrated. To do so, please refer to the relevant chapters.
Below are the two typical normal operation displays. One display page shows the partial and reset total
registers. The other shows the partial and general total. Switchover from resettable total to general total
display is automatic and tied to phases and times that are in factory set and cannot be changed.
NOTE
6 digits are available for Totals, plus two icons x 10 / x100. The
increment sequence is the following:
0.0 -> 99999.9 -> 999999 -> 100000 x 10 -> 999999 x 10
->100000 x 100 -> 999999 x 100
J1 DISPENSING IN NORMAL MODE
FOREWORD
Normal mode is the standard dispensing. While the count is made, the partial and
resettable total are displayed at the same time (reset total).
NOTE
Should one of the keys be accidentally pressed during dispens-
ing, this will have no effect.
stand by
A few seconds after dispensing has ended, on the lower register, the display
switches from resettable total to general total: the word reset above the word
total disappears, and the reset total is replaced by the general total. This situation
is called standby and remains stable until the user operates the meter again.
M0303
EN