sauter SD Series Instruction Manual

sauter SD Series Instruction Manual

Spring tester
Hide thumbs Also See for SD Series:

Advertisement

Quick Links

Model: SD, Spring Tester
Thank you for buying a SAUTER Spring Tester. We hope
you are pleased with your high quality force gauge with its
big functional range. If you have any queries, wishes or
helpful suggestions, do not hesitate to call our service
number.
Working Conditions
1.
10°C to 30°C / 15% up to 80% humidity
Operation
2.
a.
Display
(1) Measuring Result
(2) Measuring Units
(3) Activation of PRINT Function
(4) Indication of power charging status
(5) PEAK or AUTO-PEAK Mode
(6) Average value of stored peak values
(7) Force direction
(8) Occupancy of storing spaces
(9) AVERAGE- or Saving Mode
b.
Operating keys
ON / OFF:
ON / OFF key
SD-BA-e-1213
Sauter GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@sauter.eu
Instruction Manual
SD
UNIT:
ZERO:
SET:
PEAK:
Tel: +49-[0]7433- 9933-199
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
(For ON, press 1 sec.)
-
Press shortly:
Three functions:
-
Zeros the measuring result (Tara function)
-
Cleans the peak value (in Peak mode)
-
Saves a setting (in SET mode)
-
1 x Press: Upper Limit [HidT]. To change
press: ▲ or ▼ (see section c.)
HidT
-
1 x Press: Lower Limit [LodT]. To change
press ▲ or ▼ (see section c.)
Lo dT
-
1 x Press: Minimum limit to save peak
values
in
the
[LE.SET]. Please see section „Min Limit
Peak Save". To change press: ▲ or ▼
(Only in „Peak-Mode"active) (see section
g.)
LESET
-
1 x Press: Auto-Off Function. Turns the
instrument off after a here defined time
period in sec. [P.OFF]. To change press: ▲
or ▼ (Only in „Battery-Mode" active)
P.OFF
-
1 x Press: Peak-Freeze-Time [PE.2E /
A.PE / HoldT]: Time period in which a peak
value is being shown in the display in sec.
To change press: ▲ or ▼
1 x Press: Saves the Settings
Three functions
-
Track mode (continuous measurement)
-
Peak mode (capture of maximum values)
-
Auto-Peak mode, same as Peak-mode, only
without the „Min limit peak save" function
Select unit:
N, kg or lb
instrument's
memory.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SD Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for sauter SD Series

  • Page 1 Zeros the measuring result (Tara function) Cleans the peak value (in Peak mode) Saves a setting (in SET mode) Thank you for buying a SAUTER Spring Tester. We hope SET: you are pleased with your high quality force gauge with its big functional range.
  • Page 2 Sauter GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-199 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@sauter.eu Internet: www.kern-sohn.com Instruction Manual MEMORY: Saves the peak values to calculate the average value (please see section “Memory mode” DELETE Function Deletes stored peak values (only in „Memory This function allows to eliminate unwanted „Pre-Peak...
  • Page 3 The instrument may only be used in compliance with the described guidelines. Varying areas of application/ planned use must be approved by SAUTER in writing. Guarantee The guarantee is not valid following •...
  • Page 4 Sauter GmbH Ziegelei 1 Tel: +49-[0]7433- 9933-199 D-72336 Balingen Fax: +49-[0]7433-9933-149 E-Mail: info@sauter.eu Internet: www.kern-sohn.com Instruction Manual • use outside the described applications • alteration to or opening of the device • mechanical damage and damage caused by media, liquids •...

This manual is also suitable for:

Sd-ba-e-1213

Table of Contents