Programming panel
CAUTION
Equipment misoperation . Use of the control front
panel HMI may result in several combinations of
settings, configurations, and customizations . The user
must ensure that a proper combination is created and
downloaded for the appropriate device application .
The Programming panel has the following sections:
LCD display (Figure 3)
The LCD display is a 4-line, 16-character display.
The keypad functionality is summarized as follows.
The
(up) key can be used for the following tasks:
Scroll to the next item up on the current Menu level
If already at the first item of the current Menu level,
return to the last item of the current Menu
When editing a selectable option parameter, scroll up
to the next available option
Decrement the value of a digit (example: from 6 to 5)
SPEAR Single-Phase Recloser Control
→*SETTINGS
*SEQUENCE OF
EVENTS
*METERING
ENTER
ESC
EDIT
Figure 3 .
LCD display and keypad functionality
HOT LINE
The
(down) key can be used to complete the following
CLOSE
TAG
tasks:
Scroll to the next item down on current Menu level
ON
If scrolled past the last line of the current Menu level,
OFF
return to the first line of the current Menu
When editing a Selectable Option Parameter, scroll
down to the next available option
Increment the value of a digit (example: from 3 to 4)
ALARM
CONTROL OK
AC POWER
BATTERY
DATA PORT
SUPER-
NON
VISORY
RECLOSE
OFF
BATTERY
ALT
TEST
PROFILE
INSTALLATION AND OPERATION INSTRUCTIONS MN280048EN June 2016
SPEAR™ Single-Phase Recloser System
The
(left) key is used to go up one Menu level.
The
(left) key is used to move left when editing
parameters.
The
(right) key is used to go down one Menu level.
The
(right) key is used to move right when editing
parameters.
The ESC (escape) key is used for the following tasks:
G163 .0
Go back one Menu level
Cancel Edit mode when editing settings without
changing the value
The ENTER key is used for the following tasks:
Go down one Menu level
Confirm settings change in the Edit mode
Confirm resetting the Resettable Parameters
Confirm passwords
The EDIT key is used for the following tasks:
Enter the Edit mode to make a change.
Enter the Reset mode to reset the Resettable
Parameter
Status indicator LEDs
The status indicator LEDs (Figure 4 and Figure 5) in the
Programming section of the Operator Panel give instant
information on the control and recloser status:
This information is indicated on the left side of the control:
(Figure 4):
PHASE FAULT: This LED illuminates when the control
issues an overcurrent trip signal while the phase current
exceeds the programmed minimum trip value.
ABOVE MIN TRIP: This LED illuminates when the control
detects that current is above the programmed minimum
trip value.
LOCKOUT: This LED illuminates to indicate the control is
in a locked out state, i.e. a reclosing sequence is not in
progress. This LED does not indicate that the recloser is
open.
Hazardous voltage . Do not rely on the open position
of the yellow operating handle on the recloser or the
OPEN or LOCKOUT LED indicators on the recloser
control; it does not ensure that the line has been
de-energized . Always establish a visible disconnect .
Failure to follow proper safety practices can result in
contact with high voltage, which will cause death or
severe personal injury .
WARNING
G171 .0
5