Electrical wiring & Installation options

Electrical wiring

-Electrical installation must be carried out by an authorized electrician.
-The fan is double insulated and should not be grounded.
-We recommend using 3x1,5mm².

Installation options

The fan can be connected in three different ways depending on the desired function.
1.
The fan is connected with constant voltage supply 100 - 240 VAC 50/60 Hz, phase (L) and Zero (N), see wiring
diagram 1.
2.
Time control with light switch, see wiring diagram 2. The fan is connected with constant voltage supply
100 - 240 VAC 50/60 Hz, phase (L) and Zero (N). The control phase (SL) is connected to activate the fan's time
control, i.e. when the bathroom light comes on, there is power to the igniter wire. The fan will run as long as the
light is lit. When the light goes out, the fan will run for another 10 minutes.
3.
Time control with spring-loaded switch, see wiring diagram 3. The fan is connected with constant voltage supply
100 - 240 VAC 50/60 Hz, phase (L) and Zero (N). The control phase (SL) is connected to activate the fan's time
control with spring-loaded switch. The fan runs for 10 minutes after the spring-loaded switch has been activated.
100-240VAC 50/60Hz
6
SL
1
2
L
N
L
N
SL
3
L
N
EN
SL
L
N