Ac Input/Output Off; Dual Inverters: 240 Vac Loads; Figure 2-4 Ac Output Off - Xantrex ACCB Owner's Manual

Sine wave plus ac conduit box
Table of Contents

Advertisement

Operating the ACCB

AC Input/Output Off

'

Dual Inverters: 240 Vac Loads

2–4
No power to the load or charger
In this configuration, power from both the external sources of AC and the
inverter is removed from the loads. This allows the inverter, the connected
loads, or any other installed equipment beyond the
Both external AC
source and Inverter OFF
AC Input
from Grid or Gen
4
3
2

Figure 2-4 AC Output OFF

WARNING: Fire Hazard
In a series-stacked, inverter installation (120/240 Vac) with a bypass switch for
each inverter, both bypass switches must be in the same position.
If the bypass switches are not in the same position, the resulting AC output of the
two bypass switches may not be 180° out-of-phase from each other. This can
result in excess current on the neutral wire creating a potential fire hazard.
This can also result in less than 240 Vac output. Loads requiring 240 Vac will not
run.
(Figure
2-4).
ON
ON
60
60
OFF
OFF
INVERTER
INVERTER
BYPASS
DISCONNECT
BOTH OFF TO DISCONNECT AC OUTPUT
1
ACCB
to be serviced.
AC Output
to Loads
975-0046-01-01