What does this warranty cover and how long does it last? Warranty This Limited Warranty is provided by Xantrex Technology, Inc. (“Xantrex”) and covers defects in workmanship and materials in your Internal APG Interface card. This warranty lasts for a Warranty Period of 5 years from the date of purchase at point of sale to you, the original end user customer.
Page 5
Direct returns may be performed according to the Xantrex Return Material Authorization Policy described in your product manual. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantrex or check our website to see if your product can be repaired at one of these facilities. In any warranty claim, dated proof of purchase must accompany the product and the product must not have been disassembled or modified without prior written authorization by Xantrex.
Page 6
Disclaimer Product THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YOUR XANTREX PRODUCT AND IS, WHERE PERMITTED BY LAW, IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS, GUARANTEES, REPRESENTATIONS, OBLIGATIONS AND LIABILITIES, EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE IN CONNECTION WITH THE PRODUCT, HOWEVER ARISING (WHETHER BY CONTRACT, TORT, NEGLIGENCE, PRINCIPLES OF MANUFACTURER’S LIABILITY, OPERATION OF LAW, CONDUCT, STATEMENT OR OTHERWISE), INCLUDING WITHOUT RESTRICTION ANY...
Page 8
Warnings Warnings and cautions are defined and formatted in this manual as shown below. Cautions WARNING Describes a potential hazard which could result in injury or death, or, a procedure which, if not performed correctly, could result in injury or death. CAUTION Describes a procedure which, if not performed correctly, could result in damage to data, equipment, or systems.
About This Manual This manual is for the internal APG (Analog Programming) interface card for the XT and HPD Series DC output power supplies. This manual provides you with descriptions and specifications, user options, and configuration instructions which enable you to manage the power supply from an external source. This manual is designed for the user who is familiar with basic electrical theory especially as it applies to the operation of power supplies.
Page 10
About This Manual viii Operating Manual for APG for XT/HPD Series Power Supply...
Section 1. Features and Specifications Description The Analog Programming (APG) Interface is an internal option card for analog programming of XT and HPD Series DC power supplies with a 0-10Vdc programming source or a 0-10kΩ resistance. A 25-pin female DSUB connector on the unit's rear panel enables connections to the card.
Page 14
Section 1. Features and Specifications Specifications Operating Manual for APG for XT/HPD Series Power Supply...
Section 2. Installation and Configuration Introduction We usually install the APG interface in a power supply at the factory. Your local distributor or service center can also install the interface, especially for use in a previously-purchased supply already on site. Initial Inspection CAUTION If you remove the unit's cover, use proper static control techniques to avoid damage...
Configuring Configuring Configure and adjust the analog programming interface installed in your XT or HPD DC power supply as indicated in this section. The front panel LEDs indicate when V or I programming is selected (PGM), when TTL shutdown has occurred (S/D), and when the supply exceeds the voltage trip point OVP).
Rear Panel J5 Connector Rear Panel J5 Connector Make analog interface connections via the rear panel 25-pin female DSUB connector designated J5. To provide the lowest noise performance, we recommend you use shielded-twisted pair wiring for making connections from external circuits to the J5 connector.
Calibration Adjustment You can access most calibration potentiometers through the top of the unit, see Figure 2.3. The exceptions are Voltage Program OFFSET and RANGE which are on the unit's rear panel which can be seen on Figure 2.2. Figure 2.3 APG Interface Calibration Adjustment Locations Release 1.0 Calibration Adjustment...
Page 20
Section 2. Installation and Configuration Calibration Adjustment Operating Manual for APG for XT/HPD Series Power Supply...
Section 3. Operation Remote Programming Remote programming allows control of the power supply's output voltage and/or current limit to shift from local operation at the front panel voltage and current controls to external analog input sources. As you vary the programming source, the power supply's output varies proportionally over its output range.
Remote Programming 3. Vary the external voltage from 0-10Vdc to cause the power supply output to vary from 0-100% of rated output voltage. You may set the power supply's output current limit using another source or the front panel current limit control. Note:Access the zero offset adjustment through the rear panel hole labelled OFFSET.
Programming 1. Select remote current programming by external resistance by moving the rear Output panel switch S1-3 (remote current program select) to the ON (closed) position. Current with Or, connect J5 pin 8 (remote current program select) to J5 pin 6 (auxiliary a 0-10k ground).
Readback and Status Indicators Readback and Status Indicators Voltage and Voltage Readback Current • Connect a meter between J5 connector pin 19 (voltage readback) and either pin Readback 4 or 5 (program return). Range: 0-10V = 0-100% full rated voltage output of power supply Current Readback •...
Overvoltage Protection (OVP) The OVP circuit is designed to protect the load in the event of a remote programming error, incorrect voltage control adjustment, or power supply failure. The protection circuit monitors the output and reduces the output voltage and current to zero whenever a preset voltage limit is exceeded.
TTL Shutdown TTL Shutdown TTL Shutdown allows the output of the power supply to be disabled by a logic level signal. This input is optically isolated from the power supply output and will withstand a highpot test potential of 600Vac minimum. When TTL shutdown is activated, the front panel LED comes on.
Tracking For tracking +/- outputs, use the following set-up: • Set slave unit rear panel switch S1-5 (remote voltage program select) and switch S1-6 (tracking select) to ON (closed). • Connect master return (J5 connector pins 12, 13, or 24) to slave +OUT (J5 connector pins 10, 11, or 23).
Page 28
Section 3. Operation Tracking Operating Manual for APG for XT/HPD Series Power Supply...
Page 30
Xantrex Technology Inc. 8999 Nelson Way Burnaby, British Columbia Canada V5A 4B5 604 422 8595 Tel 604 421 3056 Fax 800 667 8422 Toll Free North America prg.info@xantrex.com www.xantrex.com TM-5A6H-01XN PRINTED IN CANADA...
Need help?
Do you have a question about the APG-HPD and is the answer not in the manual?
Questions and answers