B009 Serial Inputs And Outputs; B010 System Control - Rexroth Indramat Mannesmann DKC21.3 Application

For roll feeds with elc and btv04
Table of Contents

Advertisement

2-20
Standard Roll Feed

B009 Serial Inputs and Outputs

B010 System Control

0
123
maximum cycle time [ ms ] (200-500ms)
0 – no serial inputs/outputs active
1 – serial inputs/outputs active
Via the serial interface, inputs X4 and outputs X5 can be read and written
using the BTV04. The transmission rate is determined by the type of
transmission and the baud rate. The cyclic transmission is monitored by
the control. If no new telegram is received within the maximum cycle time,
the control generates the following warning or error:
E-0105 No serial real-time communication
F-0317 Serial real-time communication error
The following can be transmitted:
11 inputs, I1.03.0 to I1.04.1
12 outputs Q1.03.0 to Q1.04.2
When the inputs/outputs are activated, the keys can be read.
1
0 – Standard system control
1 – Serial system control
System control can also take place via the serial interface. Then, cyclic
transmission of the system inputs and outputs via the serial interface is
monitored. If no new telegram is received within the maximum cycle time,
the following warning or error is generated:
E-0104 No system control possible
F-0316 System control error
The warning E-0104 is generated when system control takes place via the
serial interface and the control is in 'Parameter' mode. The error F-0316 is
generated when system control takes place via the serial interface and
the control is in 'Manual' or 'Automatic' mode.