Aa00 Tasks 2 & 3; Aa05 Electrical Ventilating; Aa07 Measuring Wheel Mode; B000 Display - Rexroth Indramat Mannesmann DKC21.3 Application

For roll feeds with elc and btv04
Table of Contents

Advertisement

2-18
Standard Roll Feed
AA00 Tasks 2 & 3

AA05 Electrical Ventilating

AA07 Measuring wheel mode

B000 Display

XXXX 0035 X
number of commands in task3 per NC cycle
task 3 _ start set
if ‚0000' here, then task 3 is not switched on
task 2 – start set
12 34
output: electrical ventilating inactive
Input: electrical ventilating active
If search pins are used, then the function "electrical ven-
tilating" can be activated here via an input.
(See ELC documentation).
In preparation.
01
Input „activate measuring wheel"
Input status = 0 control via motor encoder
Input status = 1 control via measuring wheel encoder
00 = not input programmed (measuring wheel is auto-
matic - mode always active is this is programmed in pa-
rameter A100.)
1 1
reserved
Language
0 = Germany
1 = English
2 = French
3 = Spanish
4 = Italian
(in preparation)
(in preparation)
(in preparation)
DOK-SUPPL*-BTV04*ELW**-AW01-EN-P