2-12
Standard Roll Feed

F3 Contrast Settings

Diagnoses

If the contrast setting was selected in menu „Operating mode" with F3,
then the following appears:
Parameter set-up
F1-Serial Port Parameter
F2-System Parameter
F3-Save Values and Reboot
F4-Exit without Changes
6HW /&' Contrast
Fig. 2-13: Contrast setting
WKH GLVSOD\ FDQ EH DGMXVWHG WR WKH DFWXDO OLJKW FRn-
Using the arrows
ditions. If this setting is to be stored, then it is necessary to leave this
menu using the F3 key. If this menu is left using the F4 key, then the con-
trast is not stored. The previous contrast setting is retained. All other pa-
rameters that can be selected in this menu can be protected in the BTV
system parameters by inputting a password.
To receive information about the drive, then it is possible to branch off into
the diagnoses menu with „HELP".
Operating mode
XX automatic mode
DKC21.3
ECODR3-ELC-01A09
Fig. 2-14: Operating mode
The present operating mode with status number is displayed in this menu.
The connected DKC type with the firmware version also appears. Both
status messages and warnings are also displayed here.
In the event of a fault, not warnings, the diagnostics menu is automatically
switched into and the following picture appears.