Replacing The Condenser; Replacing The Starting Capacitor - Cornelius Energize 1 HC Installation And Service Manual

Undercounter
Hide thumbs Also See for Energize 1 HC:
Table of Contents

Advertisement

7.13

Replacing the condenser

Prerequisites
The sheet casing has been removed (service).
Spare parts
Condenser
1. Disconnect the electrical cables of the condenser (Fig. 34/1) on the plug (Fig. 34/2).
2. Remove the fastening nut (Fig. 35/2) from the condenser (Fig. 34/1).
3. Remove the condenser (Fig. 35/1).
4. Position the new condenser (Fig. 35/1) within the unit.
5. Attach the condenser (Fig. 35/1) using the fastening nut (Fig. 35/2).
6. Connect the electrical cables of the condenser (Fig. 34/1) to the plug (Fig. 34/2).
Finishing tasks
1. Mount the sheet casing; see chapter 7.2.
7.14

Replacing the starting capacitor

Prerequisites
The sheet casing has been removed (service).
Spare parts
Starting capacitor
1. Remove the cover (Fig. 36/1) from the electrical assembly.
2. Disconnect the electrical cables (Fig. 37/1).
3. Remove the fastening nut (Fig. 37/2) from the starting capacitor (Fig. 37/3).
4. Remove the starting capacitor (Fig. 37/3).
5. Position the new starting capacitor (Fig. 37/3) within the unit.
6. Attach the starting capacitor (Fig. 37/3) using the fastening nut (Fig. 37/2).
7. Connect the electrical cables (Fig. 37/1).
8. Attach the cover (Fig. 36/1) of the electrical assembly.
Finishing tasks
1. Mount the sheet casing; see chapter 7.2.
Installation and service manual Undercounter cooler
Energize 1 HC
24
References
see chapter 7.2
ID/reference
220046689
References
see chapter 7.2
ID/reference
450005112
Qty/
Comment
amount
1
1
Fig. 34
1
Fig. 35
Qty/
Comment
amount
1
1
Fig. 36
3
2
1
1
Fig. 37
Cornelius Deutschland GmbH
Document no. TD1001100
Version 03/08/2018, Index 2