2. Lift the fans (Fig. 31/1) with the mounting plate (Fig. 31/2) up out of the condenser (Fig. 31/3).
3. Disconnect all necessary electrical cables from the fans (Fig. 32/2).
4. Remove the fastening bolts (Fig. 32/1) from the fans (Fig. 32/2).
5. Lift the fans (Fig. 32/2) off the mounting plate (Fig. 32/3).
6. Position the new fans (Fig. 32/2) on the mounting plate (Fig. 32/3).
7. Attach the fans (Fig. 32/2), using the fastening bolts (Fig. 32/1), to the mounting plate (Fig. 32/3).
8. Connect all electrical cables to the fans (Fig. 32/2).
9. Position the fans (Fig. 31/1) with the mounting plate (Fig. 31/2) behind the condenser (Fig. 31/3).
10. Attach the mounting plate (Fig. 32/3) using the fastening bolts (Fig. 30/1).
Finishing tasks
1. Mount the control system mounting plate; see chapter 7.8.
7.12

Replacing the run capacitor for the carbonator pump

Prerequisites
The cover has been removed.
Spare parts
Run capacitor
1. Disconnect the plug (Fig. 33/3) from the run capacitor (Fig. 33/2).
2. Remove the fastening nut (Fig. 33/1) from the run capacitor (Fig. 33/2).
3. Remove the run capacitor (Fig. 33/2).
4. Position the new run capacitor (Fig. 33/2) within the unit.
5. Attach the run capacitor (Fig. 33/2) using the fastening nut (Fig. 33/1).
6. Connect the plug (/3) to the run capacitor (Fig. 33/2).
Finishing tasks
1. Mount the cover; see chapter 7.1.
Cornelius Deutschland GmbH
Document no. TD1001100
Version 03/08/2018, Index 2
References
see chapter 7.1
ID/reference
141647340
Fig. 31
1
1
1
2
3
1
Fig. 32
Qty/amount
Comment
1
3
Fig. 33
Installation and service manual Undercounter cooler
Repairs
1
2
3
1
1
1
2
1
1
2
Energize 1 HC
23