DANGER!
Risk of personal injury and equipment damage due to non-compliance with rules and regulations!
Risk of death in the case of non-compliance with rules and regulations regarding connection of the water sup-
ply!
•
In accordance with the current state of the art, install the water supply on the product using an air gap pro-
tection back flow system, a vacuum control valve or some other method that has proved effective during
tests. Installation must be carried out in compliance with all federal, state and local laws.
•
Water pipe connections and fixtures that are directly connected to the drinking water supply must be in-
stalled and serviced in compliance with federal, state and local laws.
1. At the site of installation, set up the unit on a flat surface so it cannot tilt.
2. Using quick disconnect couplings, connect the basic ingredient/drinks tubes to the relevant
connection on the unit's connecting plate (Fig. 8/3).
Observe the labels on each individual tube as you connect the tubes.
3. Connect the python (Fig. 8/1) to the quick disconnect couplings on the relevant connection on
the unit's connecting plate (Fig. 8/3).
Observe the labels on the individual tubes and connections in the connecting process; see
chapter 3.4.4.
4. Mount the cover; see chapter 7.1.
5. Perform a visual inspection. See the document "Undercounter cooler operator manual", document no. TD1001000.
6. Put the unit into service ("commissioning"); see chapter 8.1.
5.3
Removing the unit
Prerequisites
The undercounter cooler has been shut down.
Required tools/materials
Undercounter cooler cable diagram
1. Disconnect the python (Fig. 9/1) from the relevant connection on the unit's connecting plate
(Fig. 9/3).
2. Disconnect the basic ingredient/beverage tubes from the connection of the unit's relevant con-
necting plate (Fig. 9/3).
Cornelius Deutschland GmbH
Document no. TD1001100
Version 03/08/2018, Index 2
References
see chapter 8.2
ID/
reference
220046687
1
Fig. 8
Qty/
Comment
amount
1
see chapter 10.2
1
Fig. 9
Installation and service manual Undercounter cooler
Installation/removal
2
3
2
3
Energize 1 HC
13