Summer Mode Control; Floor Drying Mode - Toshiba ESTIA RUA-CP1701H Service Manual

Air to water heat pump
Hide thumbs Also See for ESTIA RUA-CP1701H:
Table of Contents

Advertisement

Monobloc Outdoor Unit
Related parameters for heating climatic curve control (predefined and custom):
Par.No
402
Heat sleep offset – (hwunooff): (K)
403
Heat away offset – (hwecooff): (K)
412
Heat curve max. set-point offset – (hcurvoff): (K)
581
Heat clim curve select – (ht_curv)
582
Heat minimum OAT – (ht_min_a): (°C)
583
Heat maximum OAT – (ht_max_a): (°C)
584
Heat min. water set-point – (ht_min_w): (°C)
585
Heat max. water set-point – (ht_max_w): (°C)
8.2.14.

Summer mode control

The summer mode control is automatically enabled based on the current outdoor air temperature (OAT). When the
summer mode is activated the system is prevented from operating in space heating mode.
Summer mode is enabled when:
OAT > summer mode OAT threshold temperature [P716] AND the summer mode ON delay [P717] time has
elapsed
OR
The summer switch input, using digital inputs DI#05 ~ DI#08, changes status from OPEN to CLOSED
Summer mode is disabled when:
OAT < summer mode OAT threshold temperature [P716] – 2K AND the summer mode OFF delay [P718] time
has elapsed
OR
The summer switch input, using digital inputs DI#05 ~ DI#08, changes status from CLOSED to OPEN
Related Parameters for summer mode control:
Par.No
042
Summer mode – (sum_mode)
502~508*
Customer switch (DI) configuration
716
Summer mode OAT threshold – (sum_oat): (°C)
717
Summer mode ON delay – (sum_ON): (hr)
718
Summer mode OFF delay – (sum_OFF): (hr)
*Parameter required depends on DI selected. For example if DI#05 is used for the summer switch function
then [P502] needs to be set to 8
Note:
i)
If OAT is not available (OAT sensor not configured or failed) then the summer mode control is reset
If the summer switch (SUMM_SW) is CLOSED then the summer mode is forced to "YES"
8.2.15.

Floor Drying Mode

The floor drying mode allows a gradual water temperature ramp-up, in heating mode, to dry the concrete floor used in
underfloor heating (UFH).
Using the software parameters it is possible to set the start and holding temperatures and the number of days for the
warm-up, ramp-up and hold periods.
At the end of the floor drying cycle the control is automatically STOPPED.
Example application for floor drying mode:
Drying starting set point [P595] = 20°C
Drying warm-up days [P596] = 3
Drying ramp-up days [P597] = 4
Drying hold-up days [P598] = 5
Heating home set point [P401] = 28
Description
Description
50
Service Manual
Range
Default
-10.0 ~ 0.0
0.0
-10.0 ~ 0.0
-5.0
-5.0 ~ 5.0
0.0
-1 ~ 12
-1
-30.0 ~ 10
-7.0
10.0 ~ 30.0
20.0
20.0 ~ 40.0
20.0
30.0 ~ 60.0
38.0
Range
Default
0 ~ 1
0
0 ~ 8
0
15.0 ~ 30.0
20.0
0 ~ 12
5
0 ~ 12
5