Honeywell HON 512 User And Maintenance Manual page 29

Gas pressure regulator with hon 650 pilot
Table of Contents

Advertisement

Pilot springs
HON 512 with HON 650 pilot user manual
Outlet pressure area p
d
range
[bar]
0.3 – 1
0.5 – 40
10 – 90
Outlet pressure area p
d
range
[bar]
0.3 – 1
0.5 – 40
10 – 90
Imperial system:
Outlet pressure area p
d
range
[bar]
0.3 – 1
0.5 – 40
10 – 90
Outlet pressure area p
d
range
[bar]
0.3 – 1
0.5 – 40
10 – 90
Specific set range W
ds
Control stage
0.3 – 1 bar
(4.4 – 14.5 psi)
0.5 – 2 bar
(7.3 – 29 psi)
1 – 5 bar
(14.5 – 72.5 psi)
2 – 10 bar
(29 – 145 psi)
5 – 20 bar
(72.5 – 290 psi)
10 – 40 bar
(145 – 580 psi)
10 – 50 bar
(145 – 725 psi)
Weight
A
[kg]
[mm]
Approx. 6.0
195
Approx. 5.0
195
Approx. 6.5
315
G
H
I
J
[mm]
[mm]
[mm]
[mm]
215
93
67
56
191
36
67
56
191
36
67
32
Weight
A
[lbs]
[in]
Approx. 13.5
7.7
Approx. 11.0
7.7
Approx. 14.5
12.4
G
H
I
J
[in]
[in]
[in]
[in]
8.5
3.7
2.6
2.2
7.5
1.4
2.6
2.2
7.5
1.4
2.6
1.3
Pilot spring
No.
Color
0
black
1
blue
2
black
3
grey
4
brown
5
red
6
Green
Description
B
C
D
E
[mm]
[mm]
[mm]
[mm]
40
29
101
26
40
27
101
26
40
27
101
26
K
L
M
N
[mm]
[mm]
[mm]
[mm]
88
230
132
90
68
209
156
-
75
202
132
-
B
C
D
E
[in]
[in]
[in]
[in]
1.6
1.2
4.0
1.0
1.6
1.1
4.0
1.0
1.6
1.1
4.0
1.0
K
L
M
N
[in]
[in]
[in]
[in]
3.5
9.1
5.2
3.5
2.7
8.2
6.1
-
3.0
8.0
5.2
-
Wire diameter [mm]
4.5
3.6
4.5
5
6.3
7.0
8/7
F
[mm]
127
127
127
O
[mm]
24
-
-
F
[in]
5.0
5.0
5.0
O
[in]
0.9
-
-
29