X-LINE ADVANCE install system rigging
Warning!
The pull back to venue shall not exceed 30° from vertical, 15° maximum on the top grid, and
15° maximum on the bottom grid.
!
Bosch Security Systems B.V.
<15º
7.
Lift the bottom of the array from the pick point hole
on the spreader bar to the desired down angle of the
array, as determined in PREVIEW.
30º
Rigging manual
Installation | en
<15º
2020-06 | V03 | F01U361023
21