Ini Reset With Master Media For Whitelist And Cardlink - Kaba 1546-K5 Operating Manual

Mechatronic cylinder compact
Table of Contents

Advertisement

Operating Manual
5.11

INI reset with master media for whitelist and CardLink

Kaba mechatronic cylinder compact
An INI reset can be used to restore the factory settings for the components.
NOTICE
All User key and master media as well as the traceback will be deleted.
Components should not be in programming mode.
INI reset for whitelist
INI reset with master
Beep
Master B
Beep
15 s
1
Beep
Master A
Beep
15 s
1
Table 6: INI reset with master media for whitelist
INI reset for CardLink
INI reset with master
Beep
Master B
Beep
15 s
1
Beep
Master A
Beep
15 s
1
Table 7: INI reset with master media for CardLink
k1evo820 - 201606
Action
B master structure
B master approx 15 s insert into
the cylinder., the INI reset will be
carried out after 15 s.
A/B master structure
A master approx 15 s insert into
the cylinder., the INI reset will be
carried out after 15 s.
Action
B master
B master approx 15 s insert into
the cylinder., the INI reset will be
carried out after 15 s.
A master
A master approx 15 s insert into
the cylinder., the INI reset will be
carried out after 15 s.
Programming
after 10 s,
1 x long,
1 x short,
after 15 s,
2 x short
after 10 s,
1 x long,
1 x short,
after 15 s,
2 x short
2 x short
2 x short
Round profile
25

Advertisement

Table of Contents
loading

Table of Contents