Cardinal 201 Installation, Technical And Operation Manual page 81

Weight transmitter
Hide thumbs Also See for 201:
Table of Contents

Advertisement

 - SMA Continuous Output Format
 - Computer Output Format
8400-M117-O1 Rev D
If SMA is selected, the data will be transmitted in the following format:
<lf><s><r><n><m><f><xxxxxx.xxx><uuu><cr>
Where:
lf =
Line Feed
s =
Flags
r =
Range
n =
Mode
m =
Motion
f =
Custom
xxxxxx.xxx = Weight
uuu =
Units
cr =
Carriage Return
If ComP is selected, the data will be transmitted in the following format:
<s><xxxxxx><d><uu><m><cc><cr>
Where:
s =
Sign
xxxxxx.xxx = Weight
d =
Decimal point
uu =
Units
m =
Mode
cc =
Weight Status
cr =
Carriage Return
Model 201 Installation & Technical
Z= center of Zero
O = Overcap
E = zero Error,
e = weight not currently being
displayed
1, 2, 3, ...
G = Gross, T = Tare, N = Net
M = Motion,
" "(blank) = no motion
Custom flag
Six digits with decimal point
lb, kg, oz, g
(hex 0D)
"-" = negative
" " (blank) = positive
Six digits
Added to string if enabled in setup
LB, KG, OZ, G
G = Gross, N = Net
OC = overcap
CZ = center of zero
MO = motion
ee = weight not currently being
displayed
(hex 0D)
Page 73

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents