Cardinal 201 Installation, Technical And Operation Manual page 100

Weight transmitter
Hide thumbs Also See for 201:
Table of Contents

Advertisement

Model 201 Installation & Technical
Page 92
fast= (Fast Target)
This is the filling target that the 201 DFC is set to fill to in the fast
part of the cycle.
Press the F3/  key to show the current setting. If the setting
displayed is acceptable, press the F3/  key again to save it.
Otherwise, use the F2/ and F1/ keys to enter a new setting
and then press the F3/  key to save it. Allowable values for Fast
Target are: 0 through scale capacity.
foUT= (Fast Output)
This is the output that is driven when fast filling is occurring. This
is a binary field to allow for driving of more than one output during
this stage of the filling cycle. For more information see the 11.2
Output Assigning section.
sLo= (Slow Target)
This is the filling target that the 201 DFC is set to fill to in the slow
part of the cycle.
Press the F3/  key to show the current setting. If the setting
displayed is acceptable, press the F3/  key again to save it.
Otherwise, use the F2/ and F1/ keys to enter a new setting
and then press the F3/  key to save it. Allowable values for
Slow Target are: 0 through scale capacity.
SoUT= (Slow Output)
This is the output that is driven when slow filling is occurring.
This is a binary field to allow for driving of more than one output
during this stage of the filling cycle. For more information see the
11.2 Output Assigning section.
8400-M117-O1 Rev D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents