Cardinal 201 Installation, Technical And Operation Manual page 78

Weight transmitter
Hide thumbs Also See for 201:
Table of Contents

Advertisement

Model 201 Installation & Technical
Page 70
 (Enable Modbus/TCP)
Press the F3/  key to show the current setting. If the setting
displayed is acceptable, press the F3/  key again to save it.
Otherwise, use the F2/ key to toggle to a new setting and then
press the F3/  key to save it. Allowable settings are:
off
on
NOTE: If rnbUS= (Enable Modbus/TCP) is Enabled (on),
the following prompts, Output Weight as... and Output
weight byte order will be active.
For= (Output Weight as...)
Press the F3/  key to show the current setting. If the setting
displayed is acceptable, press the F3/  key again to save it.
Otherwise, use the F2/ key to toggle to a new setting and then
press the F3/  key to save it. Allowable settings are:
fLoAt
int
ord= (Output Weight Byte Order)
Press the F3/  key to show the current setting. If the setting
displayed is acceptable, press the F3/  key again to save it.
Otherwise, use the F2/ key to toggle to a new setting and then
press the F3/  key to save it. Allowable settings are:
1234
Off (Modbus/TCP is Disabled)
ON (Modbus/TCP is Enabled)
Output Weight as Float
Output Weight as Integer
4321
3412
2143
8400-M117-O1 Rev D

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents