Model 201 Installation & Technical
Page 54
PArit= (Parity Setting)
Press the F3/  key to show the current setting. If the setting
displayed is acceptable, press the F3/  key again to save it.
Otherwise, use the F2/ key to toggle to a new setting and then
press the F3/  key to save it. Allowable settings are:
none
odd
euen
Stop= (Stop Bits)
Press the F3/  key to show the current setting. If the setting
displayed is acceptable, press the F3/  key again to save it.
Otherwise, use the F2/ key to toggle to a new setting and then
press the F3/  key to save it. Allowable settings are:
1
!5
2
 (Weight Mode)
Press the F3/  key to show the current setting. If the setting
displayed is acceptable, press the F3/  key again to save it.
Otherwise, use the F2/ key to toggle to a new setting and then
press the F3/  key to save it. Allowable settings are:





None = No Parity
odd = Odd Parity
Even = Even Parity
1 = One Stop Bit
1.5 = One and one half Stop Bits
2 = Two Stop Bits
Weight-On-Demand
SMA Output Format
Computer Output Format
Computer Output Format 2
Off (Weight mode is disabled)