9.2 Error and Status Codes

Page 118
The Model 201 Weight Transmitter is equipped with software that
indicates when an error in the operation takes place. The following lists
the error and status codes displayed by the 201 along with their meaning.
Should you encounter a code, please refer to this list.
Error
Calib
Calibration required
Err H
The analog input signal is high
Err L
The analog input signal is low
oCAP
The load on the scale exceeds the capacity of the scale
SrArn
SRAM error detected during startup
EEPROM CRC error detected during startup – settings
CALIB
will revert to default
E CAbl
Waiting for Ethernet
dHCP
Network configured for Dynamic Host Configuration
Protocol
dHCP b
During dHCP binding
statiC
Network configured for static IP address
P1=
First part of IP address (## . # . # . ## - e.g., 90.1.2.68)
P2=
Second part of IP address (## . # . # . ## - e.g.,
P3=
90.1.2.68)
P4=
Third part of IP address (## . # . # . ## - e.g., 90.1.2.68)
Fourth part of IP address (## . # . # . ## - e.g., 90.1.2.68)
USb
Running on USB power
boot
Boot loader mode
notArE
Attempt to select Gross/Net to show Net weight when
there is no tare weight
UnStb
Attempt to print with unstable weight
 
Attempt to zero with motion
Error O
Attempt to zero with over capacity
Error R
Attempt to zero out of range
Error d
Too many divisions configured for Legal For Trade
Meaning