2.
3.
4.
The F2 softkey is not available on the N 5" and K 5" single face model.

Setting up a station using multiple point resection

A resection sets up the station using angle/distance measurements to known points.
You can use a maximum of 10 points in a resection. Measurements can be distance
and angle, or angle only. Calculation starts automatically when enough measurements
are taken.
If there is no point name for the BS, press
on the BS field.
In the AZ field, enter the azimuth angle to the
BS point.
If you press
without entering a value in the
[ENT]
AZ field, the azimuth is automatically set to
0°00'00".
Sight the BS point and press
records are stored in the job.
You can also use the
F2
measurements. See
Advanced feature:
Measuring F1 and F2, page
Z
X1
X2
X0
Y1
[ENT]
. ST and F1
[ENT]
softkey for F1/F2
58.
X
Known point 1
(X1, Y1, Z1)
Station point (Xi, Yi, Zi)
Y0
Y2
Nikon N Series/K Series Total Station Instruction Manual
Applications 4
Known point 2
(X2, Y2, Z2)
Y
59