2 Mechanical Installation
7. Wire motor cables to the terminals U, V, W. Terminal screws have to torqued to
1.3 Nm.
8. Feed the input power cable through the M25 cable gland, and wire into the filter (L1,
L2, L3, PE). Wire control terminals as required.
W
V
U
EN 22
YASKAWA Europe TOEP C710606 101A - V1000 MMD IP65 Motor Mounted Drive - Quick Start Guide