Vibration and Shocks
Extra care should be taken with respect to vibration levels when installing or moving
the Industrial Personal Computer. If the Industrial Personal Computer is moved, for
example, while it is installed in a rack equipped with caster wheels, it can receive
excessive shock and vibration.
Installation Gasket
Use of the installation gasket may help extend the operating life of your Industrial
Personal Computer. The gasket is required to meet the protection ratings (IP65,
IP20) of the Industrial Personal Computer and provides additional protection from
vibration. Even if moisture protection is not required, install the gasket delivered with
your product.
NOTE:
EXCESSIVE VIBRATION
Plan your installation activities so that shock and vibration tolerances in the unit
are not exceeded.
Ensure that the installation panel opening and thickness are within the specified
tolerances.
Before mounting the Industrial Personal Computer into a cabinet or panel,
ensure that the installation gasket is in place. The installation gasket provides
additional protection from vibration.
Tighten the installation fasteners using a torque of 0.5 N•m (4.5 lb-in).
Failure to follow these instructions can result in injury or equipment damage.
The installation gasket is repleaceable only for Stainless Steel Bezel Model
(see page 103).
LOSS OF SEAL
Inspect the gasket prior to installation or reinstallation, and periodically as
required by your operating environment.
Replace the gasket or the complete Industrial Personal Computer if visible
scratches, tears, dirt, or excessive wear are noted during inspection.
Do not stretch the gasket unnecessarily or allow the gasket to contact the
corners or edges of the frame.
Ensure that the gasket is fully seated in the installation groove.
Install the Industrial Personal Computer into a panel that is flat and free of
scratches or dents.
Tighten the installation fasteners using a torque of 0.5 N•m (4.5 lb-in).
Failure to follow these instructions can result in injury or equipment damage.