tams elektronik LD-G-9 Manual page 19

Locomotive decoder for dc engines dcc format
Table of Contents

Advertisement

LD-G-9
CV-name
Configuration
data 2
Dimming of
the outputs:
X4
X5
X6
X7
X8
Assignment
F0 – F4 to
the outputs:
X4
X5
X6
X7
X8
CV-
Input value /
no.
(State of
delivery)
49
0 ... 127
(0)
0 ... 8
(8)
50
51
52
53
54
0 ... 31
55
56
57
58
59
Remarks
Numerical value *
Emergency stop at
change of direction
Emergency stop at F1
Shunting gear mode at F1
Shunting gear mode at F2
Shunting gear mode at F3
Shunting gear mode at F4
= The voltage that is applied to
the output.
The value "1" corresponds to
the minimum, „8" to the
maximum voltage.
Numerical value *
Operation with:
---
function key F1
function key F2
function key F3
function key F4
function key F0
English
2
2
4
8
16
32
64
2
0
1
2
4
8
16
Page 41

Advertisement

Table of Contents
loading

This manual is also suitable for:

22-01-07322-01-074 n

Table of Contents