Startup (Gas Models) - Graco DutyMax 24M054 Operation

Hydraulic sprayers
Hide thumbs Also See for DutyMax 24M054:
Table of Contents

Advertisement

Startup (Gas Models)

This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury
from pressurized fluid, such as skin injection,
splashing fluid and moving parts, follow the Pressure
Relief Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
1. Place displacement pump in grounded metal pail
partially filled with flushing fluid. Attach ground wire
to pail and to earth ground.
ti9692a
2. Turn prime valve down. Turn pressure control
counterclockwise to lowest pressure.
3. Set hydraulic pump valve OFF.
ti9686a
4. Check engine oil level. Add SAE 10W-30 (summer)
or 5W-20 (winter), if necessary.
(cold)
3A2246A
46b
ti5241a
5. Fill fuel tank.
6. Start engine.
a. Move fuel valve to open.
ti5248a
b. Move choke to closed.
ti5249a
c. Set throttle to fast.
ti5250a
d. Set engine switch to ON.
Startup (Gas Models)