Electrical Requirements - Graco DutyMax 24M054 Operation

Hydraulic sprayers
Hide thumbs Also See for DutyMax 24M054:
Table of Contents

Advertisement

Electrical Requirements

Electrical Requirements
DANGER
HIGH VOLTAGE ELECTRIC SHOCK HAZARD
This equipment uses high voltage power. Improper
contact with high voltage equipment will cause death or
serious injury.
Turn off and disconnect power cord before
servicing equipment.
This equipment must be grounded. Connect only to
grounded power source.
Use only 3-wire extension cords for 240V and
single phase models.
Use only 5-wire extension cords for 400 AC and
three phase models.
Ensure ground prongs are intact on power and
extension cords.
Do not expose to rain. Store indoors.
All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
Grounding
The equipment must be grounded to reduce the risk of
static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock. Ground-
ing provides an escape wire for the electric current.
The sprayer cord includes a grounding wire with an
appropriate grounding contact.
10
This sprayer requires circuit with a grounding recepta-
DA
cle. Never use an outlet that is not grounded.
Do not modify plug! Tampering with the plug will result in
a voided warranty. Do not use sprayer if electrical cord
has damaged ground prong.
Single Phase
If plug will not fit in outlet, have grounded outlet installed
by a qualified electrician. Do not use an adapter.
NOTE: Smaller gauge or longer extension cords may
reduce sprayer performance.
Power Requirements
230V units require 220-240 VAC, 50/60 Hz, 16A,
1 phase
380-400V units require 400 VAC, 50 Hz, 16A,
3 phase, 3P+N+E, 6H power connection
To operate the EH300DI (24M056) sprayer, the
generator needs to be sized for 15 kW output
(minimum).
Circuit Protection
Connect sprayers only to circuits which have the prop-
erly sized circuit breaker and/or fuses (for unit power
requirements see Technical Data, page 22).
ti18812a
Three Phase
ti7528b
ti7529b
ti18783a