Download Print this page

Dryer Default Codes - Dexter Laundry T-30 Original Instructions Manual

On-premise b-series control, electric-heated

Advertisement

DRYER CONTROLLER FACTORY DEFAULT PROGRAM SETTINGS
COOL DOWN
DRY
TIME
CYCLE
(MINUTES)
1
5
2
2
3
5
4
2
5
2
FAULT#
FAULT DESCRIPTION
Shorted thermostat
F1
Open thermostat
F2
F3
EEPROM corrupted.
F4
Heat relay on fault.
F5
Temperature fault.
8514-219-001 REV E PAGE 14
TOTAL CYCLE
TIME
(MINUTES)
35
20
25
20
25
DRYER FAULT CODES
Dryer stops and "F1" flashes on the 4-digit display.
When short circuit on sensor input is removed, "LOAd"
sensor.
appears on the 4-digit display and the remaining dry time
is reset.
Dryer stops and "F2" flashes on the 4-digit display.
When a good sensor is connected to sensor input, "LOAd"
sensor.
appears on the 4-digit display and the remaining dry time
is reset.
Dryer will not start and "F3" appears on the 4-digit
display. The power to the dryer must be cycled to reset
the controller. Fault should only occur when starting a
dry cycle.
The drying temperature did not increase 1
minutes. "F4" will flash on the display and the dry cycle
will finish without calling for heat (energizing heat relay).
Opening the door or pressing the STOP touch pad switch
will reset the fault and clear the remaining time in the dry
cycle.
The drying temperature is at least 25
temperature setting. "F5" will flash on the 4-digit display
and the dry cycle will finish without calling for heat
(energizing the heat relay). The power to the dryer must
be cycled to reset the controller.
DRYING
TEMPERATURE
0
0
(
F)
(
C)
180
82
Towels, pads, heavy cotton
170
77
180
82
130
54
175
79
ACTION
DRYER LOAD
Sheets, blended materials
Cotton
Synthetic materials
Blended materials
0
F. in 5
0
F. above the

Advertisement

loading

This manual is also suitable for: