Interface Specifications; Parallel Interface Specifications; Parallel Interface B Type Specifications; Figure 1-4. Timing Chart - Epson EPL-N2000 Service Manual

Hide thumbs Also See for EPL-N2000:
Table of Contents

Advertisement

EPL-N2000 Service Manual

1.3 INTERFACE SPECIFICATIONS

The following interfaces are available for EPL-N2000 printer.
Standard:
Optional:
NOTE:
Type-B I/F Board (C82331*) (standard) is inserted in the Type-B interface slot. Note the
following when Type-B I/F Board (C82331*) is installed:
Remove Type-B I/F Board (C82331*) when installing Type-B interface.
Remove Type-B I/F Board (C82331*) when using LocalTalk/Serial Module in
LocalTalk mode.
* Type-B I/F Board: C82331* ( The asterisk is a substitution for the last digit which varies
by the country.
1 : For EAI

1.3.1 Parallel Interface Specifications

1.3.1.1 Parallel Interface B Type Specifications

Type:
Operation modes:
Data transmission system:
Handshaking:
Connector type:
Applicable plug:
Cable length:
DATA 1-8
STROBE
BUSY
ACKNLG
Signal timing:
Rev. A
Parallel B type I/F
Parallel C type I/F
Network I/F
LocalTalk / Serial Module *
Type-B I/F
*
Connector for LocalTalk is built in on the I/F bracket,
along with connectors for standard I/F.
2 : For the areas other than EAI
Bidirectional Parallel I/F (IEEE-1284)
Compatibility mode
Nibble mode
ECP mode
(Byte mode and EPP mode are not supported.)
STROBE synchronization, 8-bit parallel data transfer
BUSY and ACKNLG signals
57RE-4060-730B (D5)
Receptacle:
Amphenol or equivalent
3 meters (10") or less
(1)
(2)
VALID
(3)
(4)
(5)

Figure 1-4. Timing Chart

See the figure below and Table 1-13.
(DDK)
VALID
(7)
(6)
Product Description