Download Print this page
Perfect Aire PORT8000 User Manual

Perfect Aire PORT8000 User Manual

8,000, 10,000, 12,000 & 14,000 btu
Hide thumbs Also See for PORT8000:

Advertisement

COMFORT...BUILT TO LAST
8,000, 10,000, 12,000 & 14,000 BTU
PORTABLE
AIR CONDITIONER
USER MANUAL
PORT8000
PORT10000
PORT12000
PORT14000

Advertisement

loading

Summary of Contents for Perfect Aire PORT8000

  • Page 1 COMFORT...BUILT TO LAST 8,000, 10,000, 12,000 & 14,000 BTU PORTABLE AIR CONDITIONER USER MANUAL PORT8000 PORT10000 PORT12000 PORT14000...
  • Page 2: Table Of Contents

    CONTENTS SAFETY PRECAUTIONS ..................2 IDENTIFICATION OF PARTS................3 AIR CONDITIONER FEATURES................5 OPERATING INSTRUCTIONS ................6 INSTALLATION INSTRUCTIONS ................ 8 CARE AND MAINTENANCE ................13 TROUBLESHOOTING TIPS ................14 This manual provides the information needed for proper use and maintenance of this air conditioner.
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS Always do this Never do this Do not operate your air conditioner in a wet room such as a Your air conditioner should be used in such a way bathroom or laundry room. that it is protected from moisture (i.e. condensation, Do not touch the unit with wet or damp hands or when splashed water, etc.).
  • Page 4: Identification Of Parts

    IDENTIFICATION OF PARTS • Exhaust hose 1 Set • Round mouth adaptor • Window slider kit with bolt Vent Exhaust Round Mouth Bolt Window • Vent joint Joint Hose Adaptor Slider Kit • Foam Seal 1 Piece • Remote Control and Battery 1 Set •...
  • Page 5 IDENTIFICATION OF PARTS (CONTINUED) NAMES OF PARTS Front Operation Panel Horizontal Louver Blades (adjust manually) Caster Carrying Handle (both sides) Fig.1 Rear Upper Air Filter (behind the grille) Upper Air Intake Air Outlet Power Plug Socket (used only when storing the unit Power Cord Buckle (used only when storing the unit) Power Cord Outlet...
  • Page 6: Air Conditioner Features

    AIR CONDITIONER FEATURES ELECTRONIC CONTROL OPERATING INSTRUCTIONS Before you begin, thoroughly familiarize yourself with the control panel and remote control and all its functions, then follow the symbol for the functions you desire. The unit can be controlled by the unit control panel alone or with the remote control. NOTE: This manual does not include Remote Control Operations;...
  • Page 7: Operating Instructions

    OPERATING INSTRUCTIONS COOL operation TIMER operation - Press the "MODE" button until the "COOL" If setting the timer when the unit is on: indicator light comes on. First press the TIMER button; the TIMER OFF < > - Press the ADJUST buttons “ "...
  • Page 8 Carefully tilt unit back slightly to assist the water in draining. If error does not clear after emptying, call Consumer Services. Perfect Aire Consumer Services Toll Free Number: 1.877.365.6274...
  • Page 9: Installation Instructions

    INSTALLATION INSTRUCTIONS Fig. 5 A:11.8 to 40 in. 11.8 in. Vertical window to 48.4 inches (100 cm) of (See Fig. 5.) Window Slider Kit Minimum:2.22 ft (67.5 cm) Maximum:4.04 ft (123 cm) Fig. 6 Horizontal window NOTE: If the window opening is less than 2.22 ft, Window Slider Kit cut the extension piece (see Fig.
  • Page 10 INSTALLATION INSTRUCTIONS (CONTINUED) See Fig. 8. Fig. 8 sill. See Fig. 9. See Fig. 9. 26.5" - 48" Fig. 9 Window sill See Fig. 10. See Fig. 11. Fig. 10 Window sill Fig. 11...
  • Page 11 INSTALLATION INSTRUCTIONS (CONTINUED) frame. See Fig. 12. Fig. 12 height of height of sill. See Fig. 13. 26.5" - 48" See Fig. 13. Fig. 13 See Fig. 14. See Fig. 15. Fig. 14 Fig. 15...
  • Page 12 INSTALLATION INSTRUCTIONS (CONTINUED) Fig. 16 Round Mouth Exhaust hose installation: Adaptor The exhaust hose and adaptor must be installed or removed in accordance with the usage mode as indicated below. Vent Exhaust Joint COOL or AUTO mode Install Hose Hose FAN, DRY Remove Hose Note: Flat mouth adaptor and vent joint must be threaded...
  • Page 13 INSTALLATION INSTRUCTIONS (CONTINUED) Remove the Water drainage: upper drain plug During dehumidifying mode, remove the upper drain plug from the back of the unit and attach 3/4" vinyl tube included with the unit (5/8" outer diameter). If a longer hose is needed, a vinyl tube (3/4" inner diameter 5/8"...
  • Page 14: Care And Maintenance

    CARE AND MAINTENANCE IMPORTANT: Upper filter 1) Be sure to unplug the unit before cleaning or servicing. (take out) 2) Do not use gasoline, thinner or other chemicals to clean the unit. 3) Do not wash the unit directly under a tap or using a hose. It may cause electrical danger.
  • Page 15: Troubleshooting Tips

    TROUBLESHOOTING TIPS Before calling for service, please review the chart below. Issue Possible Solutions • Be sure unit is not too large or too small for the area of the room. • Verify that all doors, windows, curtains and any other openings are closed off. Verify nothing is obstructing the airflow to/from the unit and louvers such as curtains, etc.
  • Page 16 COMFORT...BUILT TO LAST Distributed by: Perfect Aire, LLC 5151 Belt Line Rd. Suite 878 Dallas, TX 75254 877-365-6274 www.perfectaire.us Specification and performance data is subject to change without notice. Printed in China...

This manual is also suitable for: