PORTABLE AIR CONDITIONER USER MANUAL FOR MODELS: PORT8000A PORT10000A PORT12000A Before using your air conditioner, please read this manual carefully and keep it for future reference, along with your receipt.
Page 2
CONSUMER PRODUCT INFORMATION For your own records, please attach a copy of your sales receipt to this manual and complete the following: Model Number: _____________________________________ Serial Number: _______________________________________ Purchase Date: ____________________________________ Store Purchased: _____________________________________ Installation Date: ___________________________________ Installation Co.: _______________________________________ Installer Name: _____________________________________ Installer Phone No.: ___________________________________...
CONTENTS SAFETY PRECAUTIONS ..............1 IDENTIFICATION OF PARTS ............3 INSTALLATION INSTRUCTIONS .............5 CARE AND MAINTENANCE ............10 AIR CONDITIONER FEATURES ............11 OPERATING INSTRUCTIONS ............12 TROUBLESHOOTING ...............14 This manual provides the information needed for proper use and maintenance of this air conditioner. Basic preventative care can help extend the life of this unit. The “Troubleshooting”...
SAFETY PRECAUTIONS READ SAFETY PRECAUTIONS BEFORE INSTALLATION To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. NEVER DO THIS. ALWAYS DO THIS. WARNING DO NOT store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. DO NOT use an extension cord or an adapter plug; avoid fire hazard or electric shock. Do not remove any prong from the power cord.. Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the cabinet and behind the grille. Be sure the air conditioner is properly grounded. To minimize shock or fire hazards, proper grounding is import- ...
Page 5
SAFETY PRECAUTIONS Please read through these instructions before you start the installation process. Improper installation can cause damage to the unit, your personal property, and also poses a personal safety hazard. • Installation must be performed according to the installation instructions. Improper installation can cause water leakage, electrical shock, or fire. • Use only the included accessories and parts, and specified tools for the installation. Using non-standard parts can cause water leakage, electrical shock, fire, and injury or property damage. • Make sure that the outlet you are using is grounded and has the appropriate voltage. The power cord is equipped with a three-prong grounding plug to protect against shock. Voltage information can be found on the side of the unit, behind the grille. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. • Ensure the receptacle is accessible after the unit installation. • Install the unit on a flat, level, sturdy surface. Failure to do so could result in damage or excessive noise and vibration. • The unit must be kept free from obstruction to ensure proper function and to mitigate safety hazards. • DO NOT modify the length of the power cord or use an extension cord to power the unit. • DO NOT share a single outlet with other electrical appliances. Improper power supply can cause fire or electrical shock.
IDENTIFICATION OF PARTS ACCESSORIES Check that all the accessories are included in the package (Fig. 1) and refer to the installation instructions for their usage. Your Window Installation Kit fits windows 26.5 – 48 inches (67.5 – 123 cm) and can be shortened for smaller windows. Tools Needed: • Medium Phillips screwdriver • Tape measure or ruler • Knife or scissors • Saw (optional, to shorten window adapter for narrow windows) FIG. 1 PART DESCRIPTION QUANTITY Unit Adapter 1 pc Exhaust Hose 1 pc Window slider Adapter 1 pc Bolt 1 pc Window Slider A 1 pc Window Slider B 1 pc Foam Seal A (Adhesive) 2 pcs Foam Seal B (Adhesive)
Page 7
PARTS DIAGRAM FRONT REAR control panel remote signal receptor (not visible) handle horizontal louver control (both sides) lever (adjust manually) grille/air filter vertical louver control upper air intake lever (adjust manually) drain outlet air outlet panel lower air intake bottom tray caster drain outlet FIG.
INSTALLATION INSTRUCTIONS LOCATION • The air conditioner should be placed on a firm surface to minimize noise and vibration. For safe and secure positioning, place the unit on a smooth, level floor strong enough to support it. • The unit has casters to aid placement; it should only be rolled on smooth, flat surfaces. Use caution when rolling on carpeted surfaces. Do not attempt to roll the unit over objects. • The unit must be installed near a grounded plug; the Collection Tray Drain (found on the back of the unit) must be accessible. • DO NOT cover the Intakes, Outlets or Remote Signal Receptor of the unit, as this could prevent FIG.
Page 9
STEP 1: Exhaust Hose Exhaust Hose Assembly PREPARING THE EXHAUST HOSE ASSEMBLY Fig. 8 Press the exhaust hose into the window slider adapter and unit adapter; it will snap automatically to the adapters. FIG. 8 Unit Adapter Window Slider Adapter STEP 2: INSTALL THE EXHAUST HOSE ASSEMBLY TO THE UNIT...
Page 10
TYPE 1: STEP 4 Fig. 15 HUNG WINDOW INSTALLATION If desired, install the security bracket with 2 screws as shown. STEP 1 Fig. 12 Security Bracket Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown. 2 Screws Foam Seal B FIG.
Page 11
TYPE 2: STEP 4 Fig. 20 SLIDING WINDOW If desired, install the security bracket with 2 screws as shown. INSTALLATION STEP 1 Security Fig. 17 Bracket Cut the adhesive foam seal A and B strips to the proper lengths, and attach them to the window sash and frame as shown. 2 Screws Foam Seal B FIG.
Page 12
WATER DRAINAGE During dehumidifying mode, remove the drain plug Continuous from the back of the unit, install the drain connector drain hose (5/8ʺ universal female mender) with 3/4ʺ hose (locally Remove the purchased). For models without a drain connector, drain plug just attach the drain hose to the hole. Place the open end of the hose directly over the drain area in your basement floor. Be sure to store the unit and installation accessories in a cool, dark place. Exposure to direct sunshine or extreme heat can shorten the lifespan of the unit.
CARE AND MAINTENANCE CAUTION Clean air conditioner occasionally to keep it looking and operating like new. Be sure to unplug the unit before cleaning to prevent shock or fire hazards. IMPORTANT SAFETY PRECAUTIONS 1. ALWAYS unplug the unit before cleaning or servicing. 2. DO NOT use flammable liquids or chemicals to clean the unit. Grille/Air filter 3. DO NOT wash the unit under running water. Doing so causes electrical danger.
AIR CONDITIONER FEATURES Thoroughly familiarize yourself with the control panel shown below and all of its functions. Afterwards, follow the symbol for the functions you desire. This unit can be controlled by the unit control or the remote control. NOTE: This manual does not include Remote Control Operations; see the Remote Control Instructions packed with the unit for details. FIG. 24 1. MODE button 4. LED display Selects the appropriate operating mode. Each Shows the set temperature while on COOL mode.
OPERATING INSTRUCTIONS FOLLOW ME feature NOTE: Fan speeds, SLEEP mode, and FOLLOW ME feature can only be adjusted with the remote control. NOTE: This feature can be activated from the remote NOTE: When selecting a mode on the unit’s display, control ONLY. fan speed cannot be selected. The fan speed goes to The remote control serves as a remote thermostat “auto” by default. allowing for the precise temperature control at its location. To activate the FOLLOW ME feature, point COOL mode...
Page 16
P1 - Bottom Tray is Full- Remove bottom drain plug and empty the collected water into a floor drain, outdoors, or into a shallow pan. Carefully tilt unit back slightly to assist the water in draining. If error does not clear after emptying, call Consumer Services. PERFECT AIRE CONSUMER SERVICES TOLL FREE NUMBER: 1-844-472-2473...
TROUBLESHOOTING BEFORE CALLING FOR SERVICE, PLEASE REVIEW THE CHART BELOW ISSUE POSSIBLE CAUSES • Be sure unit is not too large or too small for the area of the room. • Verify that all doors, windows, curtains and any other openings are closed. Verify nothing is obstructing the front grille of unit, such as curtains, etc. • Allow enough time for room to cool, especially if outside temp is very high. • Check that the filter is not dirty and louvers are open all the way and blowing in the desired direction. AIR CONDITIONER NOT • Check that unit is set to COOL mode and that temperature is down enough (but not too low). COOLING ROOM, OR NOT BLOWING COLD AIR • If unit is near a heat source, such as a stove, etc., relocate unit. • If air coming from unit is cool to the touch, then unit is working properly; please double check the first three bullet points above. • Try using the Follow Me feature for more even cooling. • If using Follow Me remote feature, move remote away from unit. (Ensure, however, that the remote control is within 20 ft and a 180° radius of the front of the unit.) • Unplug unit for at least 5 minutes. Follow Reset instructions on plug.