7 | Performing maintenance
44 / 76
7 Performing maintenance
In this chapter, you will find the description of the required
maintenance activities and the qualifications of the staff
needed to carry out these tasks.
WARNING
The hydraulic system is under pressure during operation
Danger of bodily injury
u The hydraulic system must be depressurized before per-
forming any work on it.
7.1 Maintenance table
7.2 Changing the filter element - OLFP-3
In this chapter, you will find the procedure for changing the fil-
ter element.
To change the filter element, proceed as follows:
1. Switch off the pump in the hydraulic system or shut the
shut-off valve at the inlet IN and outlet OUT.
1x Allen wrench
2x Wrench
= 30 mm
HYDAC FILTER SYSTEMS GMBH
= 10 mm
MoWa OLFP-3-6 3819798a en-us
Need help?
Do you have a question about the OLFP-3 Series and is the answer not in the manual?