WIRING DIAGRAM / DIAGRAM PERKABELAN
Black / Hitam
Blue (Neutral) / Biru (Netral)
Brown (Live) / Coklat (Hidup)
Green/Yellow (Earth) /
Hijau/Kuning (Arde)
CONNECTING THE POWER SUPPLY / HUBUNGKAN KE ARUS LISTRIK
Only direct connection to wall switch is allowed. (as diagram below) /
Hanya gunakan pemasangan terus sakelar pada tembok. (seperti pada diagram di bawah ini)
Green/Yellow (Earth) /
Hijau/Kuning (Arde)
Earth /
Arde
* Fan Image is for illustration purpose only. / Gambar Kipas hanya untuk tujuan penggambaran.
This product is not provided with cord and plug or with other means for connection from the supply. When connect or
change the power cord or lead wire, it must be replaced by the competent personnel in order to avoid hazard. Please
use 227IEC53(RVV) or thickness of tube is 1mm or above. (Other requirements such as diameter of lead wire, please
use according to the regulation of the country). Can cause fire, explosion, short circuit, and electrical shock.
Produk ini tidak menyertakan kabel dan sakelar untuk hubungan atau pematian arus listrik. Gunakan kabel yang baik
dan berkualitas. Gunakan tipe 227IE53(RVV) atau yang ketebalan kawat lebih dari 1mm atau lebih. Gunakan syarat
dan ketentuan yang berlaku di masing-masing negara. Untuk menghindari kecelakaan, pemasangan kabel harus
dilakukan oleh orang yang berpengalaman. Dapat menyebabkan kebakaran, ledakan, korsleting, dan kejut listrik.
This product should be installed with a double poles single throw switch (Breaker Switch) with minimum 3mm contact gap in
the fixed installation circuit.
Do not use dimmer switch or regulator for this model. (It can damage the Ceiling Fan)
Produk ini harus diinstalasi dengan sakelar satu arah kutub dua (Sakelar Pemutus Arus) dengan minimum celah hubungan
3mm pada sirkit instalasi tetap.
Dilarang menggunakan alat pengatur atau sekelar peredup bagi produk ini. (Dapat merusak Kipas)
Should there be a dimmer switch or regulator, disconnect it and reconnect the wiring as below.
Jika memakai sakelar peredup atau alat pengatur, matikan, dan hubungkan kembali seperti gambar di bawah.
Regulator /
Alat Pengatur
Red / Merah
Brown /
Coklat
WARNING / PERINGATAN
ATTENTION / PERHATIAN
0
0
5
5
1
1
4
4
2
3
Regulator / Alat Pengatur
Power Supply / Catudaya
Connect Directly /
Disambung Langsung
Motor / Motor
Switch /
Brown /
Blue /
Sakelar
Coklat
Biru
Double pole single throw switch (Breaker Switch) /
Sakelar satu arah kutub dua (Sakelar Pemutus Arus)
Blue (Neutral) /
Biru (Netral)
230V
Brown (Live) /
Power Supply
Coklat (Hidup)
Catudaya
Wall Switch (OFF/ON)
Sakelar Dinding (OFF / ON)
Dimmer Switch / Sakelar Peredup
Connect Directly /
Disambung Langsung
Dimmer Switch /
Sakelar Peredup
13
Thermal Fuse / Fuse Termal
White / Putih
CN2
MAIN PCB /
PCB UTAMA
CN1
50Hz
Power Supply / Catudaya