CAUTION: Use only a plastic or brass o-ring
removal tool when removing o-rings to prevent
damage to the sealing surface. Even a small
scratch across an o-ring sealing surface could
result in leakage. Once an o-ring sealing surface
has been damaged, the part must be replaced
with new. DO NOT use a dental pick or any other
steel instrument.
5. The following acronyms are used throughout the
manual: MP is Medium Pressure; HP is High Pressure;
LP is Low Pressure.
6. Numbers in parentheses reference the key
numbers on the exploded parts schematics. For
example, in the statement, "...remove the o-ring (53)
from the valve body ...", the number 53 is the key
number to the o-ring.
NOTE: Before performing any disassembly, refer
to the exploded parts drawing, which references
all mandatory replacement parts. These parts
should be replaced with new, and must not be
reused under any circumstances, regardless of
the age of the regulator or how much use it has
received since it was last serviced.
Odyssea (Export) Technical Manual