7. Unscrew the valve seat (49) from the valve body (52) using the
spindle (47) and oldham (48).
8. Using your fingers, remove the washer (45) from the spindle
(47). Remove o-ring (46) from the groove on the spindle.
NOTE: If the washer does not come out on the spindle,
check for it inside the valve plug.
Before starting reassembly, perform parts cleaning
and lubrication in accordance with Procedure A:
Cleaning and Lubricating section of this manual.